Abstract
The light output, $α/β$ ratio, and pulse shape have been investigated at $-25^\circ$ C with PbWO$_4$ crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast $0.01-0.06 μ$s and middle $0.1-0.5 μ$s components of scintillation decay were observed for all the samples. Slow components of scintillation signal with the decay times $1-3 μ$s and $13-28 μ$s with the total intensity up to $\approx50%$ have been recognized for several samples doped by Molybdenum. We found some indications of a pulse-shape discrimination between $α$ particles and $γ$ quanta with PbWO$_4$ (Mo doped) crystal scintillators.
Explore related subjects
Keep this discovery
L. Bardelli, M. Bini, P. G. Bizzeti, F. A. Danevich, T. F. Fazzini, V. V. Kobychev, N. Krutyak, P. R. Maurenzig, V. M. Mokina, S. S. Nagorny, M. Pashkovskii, D. V. Poda, V. I. Tretyak, S. S. Yurchenko. 2007-06-16. Pulse-shape discrimination with PbWO$_4$ crystal scintillators. https://doi.org/10.1016/j.nima.2007.10.021