arXiv · 0804.2407
The Origination and Diagnostics of Uncaptured Beam in the Tevatron and Its Control by Electron Lenses
Abstract
In the Collider Run II, the Tevatron operates with 36 high intensity bunches of 980 GeV protons and antiprotons. Particles not captured by the Tevatron RF system pose a threat to quench the superconducting magnet during acceleration or at beam abort. We describe the main mechanisms for the origination of this uncaptured beam, and present measurements of its main parameters by means of a newly developed diagnostics system. The Tevatron Electron Lens is effectively used in the Collider Run II operation to remove uncaptured beam and keep its intensity in the abort gaps at a safe level.
Explore related subjects
Keep this discovery
Xiao-Long Zhang, Kip Bishofberger, Vsevolod Kamerdzhiev, Valery Lebedev, Vladimir Shiltsev, Randy Thurman-Keup, Alvin Tollestrup. 2008-04-15. The Origination and Diagnostics of Uncaptured Beam in the Tevatron and Its Control by Electron Lenses. https://doi.org/10.1103/physrevstab.11.051002
Cite the original work for its findings. Save a collection to share your selection of sources.