arXiv · 0910.4338
Half-life of the electron-capture decay of 97Ru: Precision measurement shows no temperature dependence
Abstract
We have measured the half-life of the electron-capture (ec) decay of 97Ru in a metallic environment, both at low temperature (19K), and also at room temperature. We find the half-lives at both temperatures to be the same within 0.1%. This demonstrates that a recent claim that the ec decay half-life for 7Be changes by $0.9% +/- 0.2% under similar circumstances certainly cannot be generalized to other ec decays. Our results for the half-life of 97Ru, 2.8370(14)d at room temperature and 2.8382(14)d at 19K, are consistent with, but much more precise than, previous room-temperature measurements. In addition, we have also measured the half-lives of the beta-emitters 103Ru and 105Rh at both temperatures, and found them also to be unchanged.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J. R. Goodwin, V. V. Golovko, V. E. Iacob, J. C. Hardy. 2009-10-22. Half-life of the electron-capture decay of 97Ru: Precision measurement shows no temperature dependence. https://doi.org/10.1103/physrevc.80.045501
Cite the original work for its findings. Save a collection to share your selection of sources.