arXiv · 1006.1609
Comparison of Coulomb Blockade Thermometers with the International Temperature Scale PLTS-2000
Abstract
The operation of the primary Coulomb blockade thermometer (CBT) is based on a measurement of bias voltage dependent conductance of arrays of tunnel junctions between normal metal electrodes. Here we report on a comparison of a CBT with a high accuracy realization of the PLTS-2000 temperature scale in the range from 0.008 K to 0.65 K. An overall agreement of about 1% was found for temperatures above 0.25 K. For lower temperatures increasing differences are caused by thermalization problems which are accounted for by numerical calculations based on electron-phonon decoupling.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Matthias Meschke, Jost Engert, Dieter Heyer, Jukka P. Pekola. 2010-06-08. Comparison of Coulomb Blockade Thermometers with the International Temperature Scale PLTS-2000. https://doi.org/10.1007/s10765-011-1033-8
Cite the original work for its findings. Save a collection to share your selection of sources.