The worldwide NORM production and a fully automated gamma-ray spectrometer for their characterization

Abstract

Materials containing radionuclides of natural origin, which is modified by human made processes and being subject to regulation because of their radioactivity are known as NORM. We present a brief review of the main categories of non-nuclear industries together with the levels of activity concentration in feed raw materials, products and waste, including mechanisms of radioisotope enrichments. The global management of NORM shows a high level of complexity, mainly due to different degrees of radioactivity enhancement and the huge amount of worldwide waste production. The future tendency of guidelines concerning environmental protection will require both a systematic monitoring based on the ever-increasing sampling and high performance of gamma ray spectroscopy. On the ground of these requirements a new low background fully automated high-resolution gamma-ray spectrometer MCA_Rad has been developed. The design of Pb and Cu shielding allowed to reach a background reduction of two order of magnitude with respect to laboratory radioactivity. A severe lowering of manpower cost is obtained through a fully automation system, which enables up to 24 samples to be measured without any human attendance. Two coupled HPGe detectors increase the detection efficiency, performing accurate measurements on sample volume (180 cc) with a reduction of sample transport cost of material. Details of the instrument calibration method are presented. MCA_Rad system can measure in less than one hour a typical NORM sample enriched in U and Th with some hundreds of Bq/kg, with an overall uncertainty less than 5%. Quality control of this method has been tested. Measurements of certified reference materials RGK-1, RGU-2 and RGTh-1 containing concentrations of K, U and Th comparable to NORM have been performed, resulting an overall relative discrepancy of 5% among central values within the reported uncertainty.

Explore related subjects

Keep this discovery

BibTeXRIS

G. Xhixha, GP. Bezzon, C. Broggini, GP. Buso, A. Caciolli, I. Callegari, S. De Bianchi, G. Fiorentini, E. Guastaldi, M. Kaçeli Xhixha, F. Mantovani, G. Massa, R. Menegazzo, L. Mou, A. Pasquini, C. Rossi Alvarez, M. Shyti. 2012-04-24. The worldwide NORM production and a fully automated gamma-ray spectrometer for their characterization. https://doi.org/10.1007/s10967-012-1791-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Reinvestigation of the Yield of the Trinity Device

Previous published analyses of trinitite to determine the yield of the Trinity nuclear explosion used various estimates of the fraction of fission products that became incorporated in trinitite. Furthermore, these studies utilized nuclear data that has subsequently been revised. Utilizing a planar germanium detector, we observed gamma rays produced by the decays of both 137Cs and 239Pu from four samples of trinitite. From the observed 137Cs/239Pu ratios of and a simple analysis method based on current nuclear data and weapons debris studies, we find an average yield of 9.1+-4.5 kilotons from our four samples. While this result is substantially lower than the established total yield of 21 kilotons, it is in reasonable agreement that attributable to fissions in the 239Pu core alone.

nucl-ex

Search for neutrinoless quadruple beta decay of $^{136}$Xe in PandaX-4T detector

The observation of neutrinoless quadruple beta decay (0$\nu$4$\beta$) in the absence of neutrinoless double beta decay (0$\nu$2$\beta$) has been argued to provide a strong indication that neutrinos are Dirac particles. We report a search for 0$\nu$4$\beta$ decay of $^{136}\text{Xe}$ using a total $^{136}\text{Xe}$ exposure of 148.4 kg$\cdot$yr, collected during the commissioning and the first science runs of the PandaX-4T experiment. No significant excess of events over the background is observed. A lower limit on the 0$\nu$4$\beta$ decay half-life of $^{136}\text{Xe}$ is set at 6.01 x $10^{24}$ yr at the 90% confidence level. This result establishes the most stringent constraint on this process in xenon, demonstrating the unique capability of the PandaX-4T detector in probing lepton number violation and shedding light on the fundamental nature of neutrinos.

nucl-ex

Island of Inversion in neutron-rich cobalt isotopes revealed from mass measurements

Mass measurements of the ground and isomeric states of $^{68-70}$Co have been performed using the JYFLTRAP Penning-trap mass spectrometer at the IGISOL facility. The masses were measured, either for the first time for the isomeric states of $^{68}$Co and $^{70}$Co, or with greatly improved precision for the others, removing ambiguities in the mass surface beyond $N=40$. The ordering of the low and high-spin states in $^{68}$Co and $^{70}$Co has also been established. The results, supported by Large-Scale Shell Model and Discrete Non-Orthogonal Shell-Model calculations, show a gradual lowering of intruder states with increasing neutron number, eventually leading to an inversion in $^{70}$Co. These findings clarify previously proposed contradictory interpretations. Finally, we demonstrate the importance of including induced effective 3N forces for a consistent description of binding energies in the island of inversion near $N=40$.

nucl-ex