Experimental evidence for non-axisymmetric magnetorotational instability in a rotating liquid metal exposed to an azimuthal magnetic field
Abstract
The azimuthal version of the magnetorotational instability (MRI) is a non-axisymmetric instability of a hydrodynamically stable differentially rotating flow under the influence of a purely or predominantly azimuthal magnetic field. It may be of considerable importance for destabilizing accretion disks, and plays a central role in the concept of the MRI dynamo. We report the results of a liquid metal Taylor-Couette experiment that shows the occurrence of an azimuthal MRI in the expected range of Hartmann numbers.
Explore related subjects
Keep this discovery
Martin Seilmayer, Vladimir Galindo, Gunter Gerbeth, Thomas Gundrum, Frank Stefani, Marcus Gellert, Günther Rüdiger, Manfred Schultz, Rainer Hollerbach. 2013-11-28. Experimental evidence for non-axisymmetric magnetorotational instability in a rotating liquid metal exposed to an azimuthal magnetic field. https://doi.org/10.1103/physrevlett.113.024505