arXiv · 1408.6607
A new method to suppress high-order harmonics for synchrotron radiation soft x-ray beamline
Abstract
A feasible and convenient method has been proposed to suppress higher-harmonics for varied-line-spacing (VLS) plane grating monochromator in soft x-ray region. Related calculations and experiments demonstrate that decreasing the included angle slightly by changing the parameter of exit arm length can significantly improve light purity. This method is suitable and has been used for experiments of detector calibration in beamline 4B7B at Beijing Synchrotron Radiation Facility (BSRF).
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Zhi-Ying Guo, Cai-Hao Hong, Hai-Ying Xing, Kun Tang, Yong Han, Dong-Liang Chen, Yi-Dong Zhao. 2014-08-28. A new method to suppress high-order harmonics for synchrotron radiation soft x-ray beamline. https://doi.org/10.1088/1674-1137%2F39%2F4%2F048002