Towards automated identification of changes in laboratory measurement of renal function: implications for longitudinal research and observing trends in glomerular filtration rate (GFR)

Abstract

Introduction: Kidney function is reported using estimates of glomerular filtration rate (eGFR). However, eGFR values are recorded without reference to the creatinine (SCr) assays used to derive them, and newer assays were introduced at different time points across laboratories in UK. These changes may cause systematic bias in eGFR reported in routinely collected data; even though laboratory reported eGFR values have a correction factor applied. Design: An algorithm to detect changes in SCr which affect eGFR calculation method by comparing the mapping of SCr values on to eGFR values across a time-series of paired eGFR and SCr measurements. Setting: Routinely collected primary care data from 20,000 people with the richest renal function data from the Quality Improvement in Chronic Kidney Disease (QICKD) trial. Results: The algorithm identified a change in eGFR calculation method in 80 (63%) of the 127 included practices. This change was identified in 4,736 (23.7%) patient time series analysed. This change in calibration method was found to cause a significant step change in reported eGFR values producing a systematic bias. eGFR values could not be recalibrated by applying the Modification of Diet in Renal Disease (MDRD) equation to the laboratory reported SCr values. Conclusions: This algorithm can identify laboratory changes in eGFR calculation methods and changes in SCr assay. Failure to account for these changes may misconstrue renal function changes over time. Researchers using routine eGFR data should account for these effects.

Explore related subjects

Keep this discovery

BibTeXRIS

Norman Poh, Andrew McGovern, Simon de Lusignan. 2014-09-03. Towards automated identification of changes in laboratory measurement of renal function: implications for longitudinal research and observing trends in glomerular filtration rate (GFR). https://arxiv.org/abs/1409.1542

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Biology-in-the-loop: Amortized Adaptive Hit Discovery in CRISPR Screens

Many biological discovery problems require experiments to be selected sequentially under constrained budgets. CRISPR screening is a prominent example, as exhaustive perturbation testing is often infeasible and candidate perturbations must instead be prioritized over multiple experimental rounds. Despite the importance of this problem, existing benchmarks for adaptive hit discovery remain limited in scale and diversity. Here, we introduce AssayBench-Loop, a large-scale benchmark for adaptive hit discovery comprising 1,389 CRISPR screens across five phenotype categories. Beyond enabling systematic evaluation, its scale makes it possible to learn acquisition strategies across historical experiments. Building on this resource, we introduce AssayLoop, a sequential experimental design framework combining AssayFormer, a transformer-based amortized acquisition policy trained across historical screens to adapt from experimental feedback, with LLM-derived biological priors through an adaptive handoff. In this view, completed experiments become training data for learning how accumulated evidence should guide what to test next, while LLMs provide prior biological knowledge to seed the search. We further introduce AssayLLM, showing that the same principle can be extended directly to an LLM through task-specific post-training. On temporally held-out screens, AssayLoop achieves a 5.67-fold enrichment over random selection and recovers 27.7% of hits after assaying approximately 5% of the candidate library, outperforming existing adaptive-design methods and standalone LLMs, and AssayFormer alone. Performance improves with increasing historical training data and transfers to phenotype categories excluded from training. These results demonstrate the value of learning acquisition policies across historical experiments and combining them with broad biological priors for efficient adaptive hit discovery.

q-bio.QM

Multi-Task Bacterial Colony Detection and Classification Using YOLOv8 with Edge Optimization for Resource-Constrained Deployment

Manual counting and classification of bacterial colonies are critical yet labor-intensive tasks in microbiology, prone to human error particularly on densely populated plates. This work proposes a multi-task deep learning framework trained on the Annotated Germs for Automated Recognition (AGAR) dataset (18,000 images; 9,202 training / 3,067 testing) to automate Colony Forming Unit (CFU) enumeration and species classification. A custom multi-task CNN employing global regression served as the baseline, but demonstrated limited performance in clustered colony environments due to the absence of spatial localization. To address this, a YOLOv8 object detection architecture was adopted with high-resolution 1024x1024 inputs, enabling instance-level colony detection and label assignment. The model achieved a classification accuracy of 98.13% and a counting accuracy of 98.27% (within a 10-colony margin), demonstrating strong predictive capability. To bridge the gap between model performance and practical deployability, the trained model was optimized through unstructured and structured pruning, ONNX conversion, and reduced-precision inference (FP32, FP16, INT8). On a Raspberry Pi 4B, ONNX FP32 and FP16 variants offered the best balance between inference speed (~6.4s) and accuracy (MAE ~2.20). Unstructured pruning preserved predictive accuracy (MAE ~2.01) without runtime gains, while structured pruning resulted in significant accuracy degradation (MAE ~6.3), revealing the sensitivity of instance-level colony detection to architectural compression. These findings provide practical guidance for selecting optimization strategies in resource-constrained laboratory deployments.

q-bio.QM

ADMET-EvO: a self-evolving scientific agent for sustained research across heterogeneous tasks

Scientific agents can move beyond automated model building by using accumulated evidence to revise both their questions and experimental strategies. The challenge is sustaining this adaptation across heterogeneous tasks without overfitting decisions to internal validation. Absorption, distribution, metabolism, excretion and toxicity (ADMET) prediction provides a demanding setting across diverse assays, datasets and chemical domains. We therefore developed ADMET-EvO, an evidence-gated agent that formalizes endpoints, generates falsifiable hypotheses and tests interventions across data, feature and model axes. It carries supported, rejected and inconclusive outcomes forward to guide each new cycle. Across the 22-task Therapeutics Data Commons (TDC) ADMET benchmark, ADMET-EvO achieved the highest task-normalized score of 96.77. Evidence-guided selection reduced cumulative fitting time by 72.2% within a predefined non-inferiority margin. It also formalized 43 toxicity-related tasks and constructed endpoint-specific predictors. Together, these results show how ADMET-EvO can accumulate evidence, revise its strategy and expand its research scope over time.

q-bio.QM