Abstract

CODYRUN is a multi-zone software integrating thermal building simulation, airflow, and pollutant transfer. A first question thus arose as to the integration of indoor lighting conditions into the simulation, leading to a new model calculating natural and artificial lighting. The results of this new daylighting module were then compared with results of other simulation codes and experimental cases both in artificial and natural environments. Excellent agreements were obtained, such as the values for luminous efficiencies in a tropical and humid climate. In this paper, a comparison of the model output with detailed measures is presented using a dedicated test cell in Reunion Island (French overseas territory in the Indian Ocean), thus confirming the interest for thermal and daylighting designs in low-energy buildings. Introduction Several software packages are available for thermal and airflow simulation in buildings. The most frequently used are ENERGY+ [1], ESP-r [2], and TRNSYS [3]. These applications allow an increasing number of models to be integrated, such as airflow, pollutant transport, and daylighting. In the latter category, we may note ENERGY+, ESP-r and ECOTECT [4] software. After more than 20 years of developing a specific code named CODYRUN, we decided to add a lighting module to our software. This paper therefore provides some details on this evolution and elements of validation. The CODYRUN initial software and its validation Developed by the Physics and Mathematical Engineering Laboratory for Energy and Environment at the University of Reunion Island, CODYRUN [5-14] is a multi-zone software program integrating ventilation and moisture transport transfer in buildings. The software employs a zone approach based on nodal analysis and resolves a coupled system describing thermal and airflow phenomena. Numerous validation tests of the CODYRUN code were successfully applied to the software. Apart from the daylighting model, the majority applied the BESTEST procedure [15]. The International Energy Agency (IEA) sponsors a number of programs to improve the use and associated technologies of energy. The National Renewable Energy Laboratory (NREL) developed BESTEST, which is a method based on comparative testing of building simulation programs, on the IEA's behalf. The procedure consists of a series of test cases buildings that are designed to isolate individual aspects of building energy and test the extremes of a program. As the modelling approach is very different between codes, the test cases are specified so that input equivalency can be defined thus allowing the different cases to be modelled by most of codes. The basis for comparison is a range of results from a number of programs considered to be a state-of-art in United States and Europe. Associated with other specific comparisons, a very confident level of validation was obtained for the CODYRUN initial software [8].

Explore related subjects

Keep this discovery

BibTeXRIS

H. Boyer, S. Guichard, A. Jean, T. Libelle, Dimitri Bigot, F. Miranville, M. Bojić. 2015-09-14. Validation of daylighting model in CODYRUN building simulation code. https://arxiv.org/abs/1509.04738

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Circular Economy Synergies and Trade-offs in Data Centres

This report analyses data centre (DC) sustainability and circularity, revealing existing synergies and trade-offs: The PUE is too coarse, mixing cooling and power provisioning. It wrongly attributes server fan consumption and transformation losses to IT energy. It does not measure compute but infrastructure efficiency, which is already outstanding. Compute energy, however, is exploding. Better energy metrics for DCs would thus cover i) compute efficiency, ii) transformation efficiency, and iii) cooling overhead. Trade-offs exist between cooling energy and water as well as on-site and upstream water: Consuming water on-site lowers the cooling energy, which also lowers the water consumed upstream in power generation. For 'wet' electricity, there is little competition: It is worth spending more on-site energy to save both electricity and related upstream water. For 'dry' electricity, there is a trade-off. Waste heat recovery brings energy circularity but has limited uses and is not the same energy quality, a fact not reflected by current metrics. A better metric would consider the avoided energy through heat recovery instead of the amount recovered. Material circularity can be achieved by interpreting the 9R framework in the context of DCs. Circularity-enhancing measures can be categorised into product design, process design and business models, choice of materials, and operating conditions. Together, they have effects across all circularity levels. The relation between DCs and the power grid is complex. Modern DCs present new challenges for the grid. Mitigation includes battery storage and onsite generation. These measures have, in turn, further consequences, both beneficial and detrimental. They can offer grid flexibility as well as innovations in the field of energy. But they also bring noise, pollution, and GHGs, and compete with the energy sector for resources.

cs.OH

Digital Twin Modeling of a Highly Automated Agricultural Tractor

In efforts to increase research efficiency and availability, a digital twin of our research tractor (AMX G-trac) is created, focusing especially on the CAN communication for data reading and actuation command following the ISOBUS protocol. Mevea Simulation Software is utilized as the foundation, providing the kinematic model and visuals, while Python is used to read and write CAN messages over a Kvaser CanKing virtual CAN channel. Various performance tests involving straight line and turning behavior are performed in both the digital twin simulation and in the real world to measure similarity. Results indicate that the Mevea model behaves very comparable in its lateral dynamics, often within 5-10 percent, but requires better data to fully capture the longitudinal aspects like acceleration. The final model described in this paper sets the table for a second iteration to include more tractor functions such as hydraulics and tractor-implement dynamics.

cs.OH

Risk-based Design for Sustainability in Cloud Systems: Insights from an Experts' Survey

Cloud Systems' Sustainability is critical in Cloud Computing, especially with the growing demand in many industries. Sustainability risks in Cloud Computing can be tricky, mostly because of system complexity and their impact on performance. Thus, this research focuses on Risk-based design (RBD) and how it can support the early identification of possible risks for Cloud System Sustainability, as well as respective mitigation strategies of each risk. In order to successfully identify risks of Cloud System Sustainability, an Expert Survey is conducted including experts with different roles from different industries, to identify possible sustainability risks of a Cloud System on all different levels. Thematic analysis of the responses resulted in a categorization of risks, as well as in the identification of mitigation strategies and factors affecting each risk. Such findings can be helpful for researchers and practitioners that utilize RBD when building sustainable Cloud systems.

cs.OH