arXiv · 1607.06776
The USNO rubidium fountains
Abstract
Four rubidium fountains at the U.S. Naval Observatory (USNO) have been in operation for 4.5 years. Each fountain has demonstrated periods of stability marked by Total or Theo deviation below 10^-16. Occasional frequency changes, on order of 1.5 times per year per fountain, introduce deviations from white-frequency noise behavior. Averaged together, the four fountains form an ensemble with a white-frequency noise level of 10^-13 and excellent long-term stability as compared to the primary frequency standards contributing to TAI. Progress on using the clocks at USNO for improving limits on coupling of fundamental constants to gravity by measuring the universality of the gravitational redshift for different types of clocks is discussed.
Explore related subjects
Keep this discovery
Steven Peil, James Hanssen, Thomas B. Swanson, Jennifer Taylor, Christopher R. Ekstrom. 2016-07-22. The USNO rubidium fountains. https://doi.org/10.1088/1742-6596%2F723%2F1%2F012004
Cite the original work for its findings. Save a collection to share your selection of sources.