arXiv · 1703.09334
Electron neutral collision frequency measurement with the hairpin resonator probe
Abstract
Electron neutral collision frequency is measured using both grounded and floating hairpin resonator probes in a 27 MHz parallel plate capacitively coupled plasma (CCP). Operating conditions are 0.1-2 Torr (13.3-267 Pa) in Ar, He, and Ar-He gas mixtures. The method treats the hairpin probe as a two wire transmission line immersed in a dielectric medium. A minimization method is applied during the pressure and sheath correction process by sweeping over assumed collision frequencies in order to obtain the measured collision frequency. Results are compared to hybrid plasma equipment module (HPEM) simulations and show good agreement.
Explore related subjects
Keep this discovery
David J Peterson, Philip Kraus, Thai Cheng Chua, Lynda Larson, Steven C Shannon. 2017-03-27. Electron neutral collision frequency measurement with the hairpin resonator probe. https://doi.org/10.1088/1361-6595/aa80fa
Cite the original work for its findings. Save a collection to share your selection of sources.