arXiv · 1901.01207
How to accurately determine a saturation magnetization of the sample in a ferromagnetic resonance experiment?
Abstract
The phenomenon of ferromagnetic resonance (FMR) is still being exploited for determining the magnetocrystalline anisotropy constants of magnetic materials. We show that one can also determine accurately the saturation magnetization of the sample using results of FMR experiments after taking into account the relationship between resonance frequency and curvature of the spatial distribution of free energy at resonance. Specifically, three examples are given of calculating saturation magnetization from FMR data: we use historical Bickford's measurements from 1950 for bulk magnetite, Liu's measurements from 2007 for a 500 mn thin film of a weak ferromagnet (Ga, Mn)As, and Wang's measurements from 2014 for an ultrathin film of YIG. In all three cases, the magnetization values we have determined are consistent with the results of measurements.
Explore related subjects
Keep this discovery
P. Tomczak, H. Puszkarski. 2019-01-04. How to accurately determine a saturation magnetization of the sample in a ferromagnetic resonance experiment?. https://arxiv.org/abs/1901.01207
Cite the original work for its findings. Save a collection to share your selection of sources.