arXiv · 1902.02649
XBioSiP: A Methodology for Approximate Bio-Signal Processing at the Edge
Abstract
Bio-signals exhibit high redundancy, and the algorithms for their processing are inherently error resilient. This property can be leveraged to improve the energy-efficiency of IoT-Edge (wearables) through the emerging trend of approximate computing. This paper presents XBioSiP, a novel methodology for approximate bio-signal processing that employs two quality evaluation stages, during the pre-processing and bio-signal processing stages, to determine the approximation parameters. It thereby achieves high energy savings while satisfying the user-determined quality constraint. Our methodology achieves, up to 19x and 22x reduction in the energy consumption of a QRS peak detection algorithm for 0% and <1% loss in peak detection accuracy, respectively.
Explore related subjects
Keep this discovery
Bharath Srinivas Prabakaran, Semeen Rehman, Muhammad Shafique. 2019-02-05. XBioSiP: A Methodology for Approximate Bio-Signal Processing at the Edge. https://doi.org/10.1145/3316781.3317933
Cite the original work for its findings. Save a collection to share your selection of sources.