arXiv · 2007.02358
Contour-based Bone Axis Detection for X-Ray Guided Surgery on the Knee
Abstract
The anatomical axis of long bones is an important reference line for guiding fracture reduction and assisting in the correct placement of guide pins, screws, and implants in orthopedics and trauma surgery. This study investigates an automatic approach for detection of such axes on X-ray images based on the segmentation contour of the bone. For this purpose, we use the medically established two-line method and translate it into a learning-based approach. The proposed method is evaluated on 38 clinical test images of the femoral and tibial bone and achieves a median angulation error of 0.19° and 0.33° respectively. An inter-rater study with three trauma surgery experts confirms reliability of the method and recommends further clinical application.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Florian Kordon, Andreas Maier, Benedict Swartman, Maxim Privalov, Jan Siad El Barbari, Holger Kunze. 2020-07-05. Contour-based Bone Axis Detection for X-Ray Guided Surgery on the Knee. https://arxiv.org/abs/2007.02358
Cite the original work for its findings. Save a collection to share your selection of sources.