SearcharxivSearch

arXiv · 2008.13718

Left atrial ejection fraction estimation using SEGANet for fully automated segmentation of CINE MRI

Abstract

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, characterised by a rapid and irregular electrical activation of the atria. Treatments for AF are often ineffective and few atrial biomarkers exist to automatically characterise atrial function and aid in treatment selection for AF. Clinical metrics of left atrial (LA) function, such as ejection fraction (EF) and active atrial contraction ejection fraction (aEF), are promising, but have until now typically relied on volume estimations extrapolated from single-slice images. In this work, we study volumetric functional biomarkers of the LA using a fully automatic SEGmentation of the left Atrium based on a convolutional neural Network (SEGANet). SEGANet was trained using a dedicated data augmentation scheme to segment the LA, across all cardiac phases, in short axis dynamic (CINE) Magnetic Resonance Images (MRI) acquired with full cardiac coverage. Using the automatic segmentations, we plotted volumetric time curves for the LA and estimated LA EF and aEF automatically. The proposed method yields high quality segmentations that compare well with manual segmentations (Dice scores [$0.93 \pm 0.04$], median contour [$0.75 \pm 0.31$] mm and Hausdorff distances [$4.59 \pm 2.06$] mm). LA EF and aEF are also in agreement with literature values and are significantly higher in AF patients than in healthy volunteers. Our work opens up the possibility of automatically estimating LA volumes and functional biomarkers from multi-slice CINE MRI, bypassing the limitations of current single-slice methods and improving the characterisation of atrial function in AF patients.

Explore related subjects

Keep this discovery

BibTeXRIS

Ana Lourenço, Eric Kerfoot, Connor Dibblin, Ebraham Alskaf, Mustafa Anjari, Anil A Bharath, Andrew P King, Henry Chubb, Teresa M Correia, Marta Varela. 2020-08-31. Left atrial ejection fraction estimation using SEGANet for fully automated segmentation of CINE MRI. https://arxiv.org/abs/2008.13718

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV