SearcharxivSearch

arXiv · 2011.00744

Clinical Evaluation of Real-Time Optical-Tracking Navigation and Live Time-Intensity Curves to Provide Feedback During Blinded 4D Contrast-Enhanced Ultrasound Imaging

Abstract

Current commercial matrix transducers for 3D DCE-US do not display side-by-side B-mode and contrast-mode images when capturing volumetric data, thus leaving the operator with no position feedback during lengthy acquisitions. The purpose of this study was to investigate the use of transducer tracking to provide positioning feedback and to re-align images to improve quantification. An interventional tracking system was developed in house using an infrared camera and a 3D-printed tracking target attached to a X6-1 matrix transducer. The system displays a virtual probe on a separate screen and allows to capture a reference position to provide operator feedback when no B-mode image is available. To test this set-up, five experienced operators were asked to locate an image landmark within a volunteer liver in B-mode images using the X6-1 connected to an EPIQ7 system. Operators were then asked to maintain the transducer position for 4 minutes under three feedback methods: i) B-mode, ii) display of real-time virtual transducer, iii) blind. The magnitude of displacement over the cine was computed as an estimate of the imaging position error. We also investigated whether transducer coordinates can be used to re-align images due to motion and improve contrast ultrasound perfusion repeatability. A total of 8 patient data were obtained under an IRB for this. Results suggest that tracking can assist operators maintain a steady position during a lengthy acquisition. With blinded acquisition, an average displacement of 4.58 mm (S.D. 2.65 mm) was noted. In contrast, the average displacement for tracking-feedback was comparable to B-mode at 3.48 mm (S.D. 0.8 mm). We also observed that perfusion parameters had better repeatability after re-alignment.

Explore related subjects

Keep this discovery

BibTeXRIS

Ahmed El Kaffas, Renhui Gong, Samvardhini Sridharan, Rosa Maria Silveira Sigrist, Isabelle Durot, Jürgen K. Willmann, Dimitre Hristov. 2020-11-02. Clinical Evaluation of Real-Time Optical-Tracking Navigation and Live Time-Intensity Curves to Provide Feedback During Blinded 4D Contrast-Enhanced Ultrasound Imaging. https://arxiv.org/abs/2011.00744

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV