SearcharxivSearch

arXiv · 2101.06963

Uncertainty-Aware Body Composition Analysis with Deep Regression Ensembles on UK Biobank MRI

Abstract

Along with rich health-related metadata, medical images have been acquired for over 40,000 male and female UK Biobank participants, aged 44-82, since 2014. Phenotypes derived from these images, such as measurements of body composition from MRI, can reveal new links between genetics, cardiovascular disease, and metabolic conditions. In this work, six measurements of body composition and adipose tissues were automatically estimated by image-based, deep regression with ResNet50 neural networks from neck-to-knee body MRI. Despite the potential for high speed and accuracy, these networks produce no output segmentations that could indicate the reliability of individual measurements. The presented experiments therefore examine uncertainty quantification with mean-variance regression and ensembling to estimate individual measurement errors and thereby identify potential outliers, anomalies, and other failure cases automatically. In 10-fold cross-validation on data of about 8,500 subjects, mean-variance regression and ensembling showed complementary benefits, reducing the mean absolute error across all predictions by 12%. Both improved the calibration of uncertainties and their ability to identify high prediction errors. With intra-class correlation coefficients (ICC) above 0.97, all targets except the liver fat content yielded relative measurement errors below 5%. Testing on another 1,000 subjects showed consistent performance, and the method was finally deployed for inference to 30,000 subjects with missing reference values. The results indicate that deep regression ensembles could ultimately provide automated, uncertainty-aware measurements of body composition for more than 120,000 UK Biobank neck-to-knee body MRI that are to be acquired within the coming years.

Explore related subjects

Keep this discovery

BibTeXRIS

Taro Langner, Fredrik K. Gustafsson, Benny Avelin, Robin Strand, Håkan Ahlström, Joel Kullberg. 2021-01-18. Uncertainty-Aware Body Composition Analysis with Deep Regression Ensembles on UK Biobank MRI. https://arxiv.org/abs/2101.06963

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV