Temperature selective thermometry with sub-microsecond time resolution using dressed-spin states in diamond
Abstract
Versatile nanoscale sensors that are susceptible to changes in a variety of physical quantities often exhibit limited selectivity. This paper reports a novel scheme based on microwave-dressed spin states for optically probed nanoscale temperature detection using diamond quantum sensors, which provides selective sensitivity to temperature changes. By combining this scheme with a continuous pump-probe scheme using ensemble nitrogen-vacancy centers in nanodiamonds, a sub-microsecond temporal resolution with thermal sensitivity of 3.7 K$\cdot$Hz$^{-1/2}$ that is insensitive to variations in external magnetic fields on the order of 2 G is demonstrated. The presented results are favorable for the practical application of time-resolved nanoscale quantum sensing, where temperature imaging is required under fluctuating magnetic fields.
Explore related subjects
Keep this discovery
Jiwon Yun, Kiho Kim, Sungjoon Park, Dohun Kim. 2021-05-08. Temperature selective thermometry with sub-microsecond time resolution using dressed-spin states in diamond. https://doi.org/10.1002/qute.202100084
Cite the original work for its findings. Save a collection to share your selection of sources.