SearcharxivSearch

arXiv · 2105.10231

Cerium (III) and (IV) containing mesoporous glasses/alginate beads for bone regeneration: bioactivity, biocompatibility and reactive oxygen species activity

Abstract

A very small number of biomaterials investigated for bone regeneration was reported as able to prevent the oxidative stress. In this study beads based on alginate hydrogel and mesoporous glasses (MG) containing different amounts of cerium oxides (Ce3+/Ce4+) exhibiting antioxidant properties were investigated as a good approach to mimic the action of antioxidant enzymes in our organism. The effect of cerium contents on the bioactivity and biocompatibility of beads were investigated. Moreover, the potential capability of Ce-containing MG to prevent the oxidative stress caused by the activity of reactive oxygen species (ROS) was here investigated for the first time. The increment of cerium oxide from 1.2, to 3.6 and 5.3 mol-% decreases the surface area and porosity of MG and increases the catalase mimetic activity after 168 h. Swelling tests in different cell culture media (D- and {\alpha}-MEM) demonstrated the rehydration capability of beads. The presence of beads with the highest Ce-contents (3.6 and 5.3 %) improved the proliferation of pre-osteoblastic cells MC3T3-C1 cells. However, the cell differentiation decreased when increased the cerium content. Lactate dehydrogenase assays showed beads are cytocompatible materials. Moreover, oxidative stress tests with H2O2 showed a better response related to cell viability and the elimination of oxidant species when increased cerium content. Beads of glasses with 1.2 and 3.6 % of CeO2 are excellent candidates as bioactive scaffolds for bone regeneration capable of counteract the oxidative stress.

Explore related subjects

Keep this discovery

BibTeXRIS

E. Varini, S. Sanchez-Salcedo, G. Malavasi, G. Lusvardi, M. Vallet-Regi, A. J. Salinas. 2021-05-21. Cerium (III) and (IV) containing mesoporous glasses/alginate beads for bone regeneration: bioactivity, biocompatibility and reactive oxygen species activity. https://doi.org/10.1016/j.msec.2019.109971

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Adaptive therapy under parametric, structural, and measurement uncertainty

Adaptive therapy has emerged as a promising treatment strategy that exploits within-tumour competition to delay disease progression. Implementation, however, typically relies on indirect measurements of tumour burden and must account for potentially substantial patient heterogeneity. In this work, we capture patient-to-patient variability, parameter uncertainty, and imperfect biomarker measurements with a mathematical and statistical model that we calibrate to clinical prostate cancer data using a Bayesian inference framework. We use the resulting virtual cohort to demonstrate that, within the simple but now well-established Lotka-Volterra-based model, adaptive therapy robustly improves time-to-progression for the subset of patients that are predicted to eventually progress by the model. To account for other risk factors associated with larger tumour volumes, we introduce a new metric based on the risk of metastasis that demonstrates how adaptive therapy may be disadvantageous when sustained tumour burden is also considered. Given the ubiquity of uncertainty in oncology, we then describe several future modelling directions that also capture uncertainty in the temporal evolution of the underlying tumour or biomarker dynamics. Finally, we demonstrate how model misspecification and non-identifiability can lead to unreliable predictions, especially if uncertainty is inadequately captured.

q-bio.TO

Head Impact Characterization and Cellular Response of a Live-neuron cell-integrated Biomechanical Full-body Surrogate Model

In this study, we develop a novel integrated framework that links the impact response with cellular dynamics using a live-neuron cell-integrated biomechanical full-body surrogate model. The impact event is simulated by allowing the surrogate model to fall from controlled seated release angles of 30-degree, 60-degree, and 90-degree. Three vertically stacked cell-culture Petri dishes, each containing live SH-SY5Y neuroblastoma cells, were placed inside the head of a commercially available surrogate model. The dynamic response of the impact event was evaluated using acceleration measurements from six accelerometers, comprising three sensors mounted on the head surface and three embedded in series with the cell stacks, along with kinematic measurements of the fall and deformation of the head model. In parallel, an OpenSim-based modified musculoskeletal model was used to simulate the fall experiment. We found that variation in contact stiffness produced the largest change in the predicted head acceleration in the simulation. When the cellular response and the measured accelerations are compared, oxidative stress and cell viability showed trends consistent with the regional acceleration and angle of fall. At the 90-degree fall, where median peak linear accelerations ranged from 170-258g, and the maximum headform deformation was approximately 9.4 mm, oxidative stress increased to approximately twice that of the control sample. We also quantified the cellular drift of SH-SY5Y cells, which is focal in nature for the 90-degree impact condition. The corresponding fall scenarios were also simulated in OpenSim and a preliminary calibration relationship was developed to compare the kinematic responses of the physical surrogate and musculoskeletal model. Finally, the framework provides a basis for relating experimental surrogate measurements to human head-neck response during impact.

q-bio.TO

History Matters: Damage-Mediated Amplification of Brain Deformation and Injury Risk under Repeated Head Impacts

Computational head models are typically applied to isolated impacts, leaving repeated head loading largely unexplored. An Ogden-Roxburgh Mullins damage formulation was implemented in a high-fidelity finite element head model to represent loading-history-dependent softening during cyclic brain-tissue deformation. Repeated-loading histories derived from mixed martial arts head-impact data were applied and compared with damage-free hyperelastic (HE) and linear visco-hyperelastic (LVHE) model variants. Under five identical single-axis cycles, Mullins-type softening progressively increased strain and strain rate metrics relative to the HE model. Mullins-based injury probabilities progressively exceeded strain-based HE predictions and diverged from unchanged kinematics-based predictions, indicating that neglecting prior softening may underestimate injury risk. In a randomized twenty-cycle multiaxial sequence, cycles of similar kinematic intensity produced different deformation and injury-risk estimates depending on prior softening. HE and LVHE models predicted higher injury probabilities initially, whereas the Mullins-based model produced the largest later-cycle estimates and highest probability of at least one injury over the sequence. Regional amplification depended on loading direction and prior softening, with no direction-independent trend among brain substructures. Gyral elements exhibited higher cumulative maximum principal strain than sulcal elements, which showed greater amplification relative to initial responses. These findings demonstrate that short-term damage-mediated softening can substantially amplify tissue deformation and injury-risk estimates beyond damage-free head models under the same loading histories. Further experimental characterization of cyclic brain-tissue softening is needed to improve models of repeated head loading and traumatic brain injury.

q-bio.TO