arXiv · 2108.07230
Simple Formulas for Output Interception Power Estimation of Uni-Traveling Carrier Photodiodes
Abstract
Simple analytical expressions for estimation of second order output intercept point (OIP2) and third order output intercept point (OIP3) of surface normal uni-traveling carrier (UTC) and modified uni-traveling carrier (MUTC) photodiode (PD) are derived. These equations are valuable for estimation of OIP for high power (M)UTC-PDs during the design phase.
Explore related subjects
Keep this discovery
Keye Sun, Junyi Gao, Yuan Yuan, Joe. C. Campbell, Andreas. Beling. 2021-08-16. Simple Formulas for Output Interception Power Estimation of Uni-Traveling Carrier Photodiodes. https://arxiv.org/abs/2108.07230
Cite the original work for its findings. Save a collection to share your selection of sources.