SearcharxivSearch

arXiv · 2110.12878

Monofiber optical probe using Doppler signals detection for Drop Size and Velocity measurement in air assisted atomization

Abstract

Reliable measurement of droplet/bubble size and velocity distributions in dense flows is desired in a variety of research fields, both for laboratory and industrial use. A new type of single-mode monofiber optical probe manufactured by A2 Photonic Sensors is introduced in this paper: it combines traditional phase detection with the collection of a Doppler signal returned by an incoming gas-liquid interface to provide information on residence times, drop concentration and velocity, which afford then drop chords and liquid flux measurements. Compared with classical optical probes, that new sensor does not require any calibration. The purpose of the present work is to test this technique in assisted atomization in order to provide a mean for spray characterization and ultimately to improve our understanding of atomization mechanisms. The probe has been tested downstream of a coaxial air-assisted atomizer operated at liquid velocity =. to. / , and gas velocity from = to about /. We first analyzed raw signals in various flow conditions. It happens that, when increasing the gas velocity and the number density of drops, the signal experiences very strong fluctuations of the gas level, making the identification of individual droplets more difficult. That leads us to develop a new signal processing routine specifically adapted to such complex working conditions. At = / and for three liquid flow rates, the spatial integration of local liquid fluxes represents 92 to 99% of the injected liquid flow rate. These good results demonstrate that the Doppler probe provides reliable statistics on drops velocity and size.

Explore related subjects

Keep this discovery

BibTeXRIS

Mathieu Alonzo, Anthony Lefebvre, Zhujun Huang, Stéphane Gluck, Alain Cartellier. 2021-10-18. Monofiber optical probe using Doppler signals detection for Drop Size and Velocity measurement in air assisted atomization. https://arxiv.org/abs/2110.12878

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Scattering-robust Imaging of Azimuthal Features with Enhanced Resolution

Imaging through scattering media remains a long-standing challenge in numerous real-world applications, ranging from medical imaging to long-distance sensing. Recently, illumination consisting of a single orbital angular momentum (OAM) mode, which is structured in the azimuthal coordinate, has been shown to provide enhanced resolution for imaging objects with azimuthal features, with the resolution becoming maximum at an optimal OAM value. However, in the presence of scattering, single-mode fields, which are spatially fully coherent, cause the imaging resolution to decrease significantly due to speckle formation. In this work, we employ azimuthally partially coherent fields and experimentally demonstrate imaging of azimuthal features with enhanced resolution in the presence of scattering. We show that lower degree of azimuthal coherence in such illumination leads to increased robustness against scattering while the azimuthal structure of the illumination ensures enhanced resolution. We derive the condition for best imaging resolution, and we report increase of imaging contrast in scattering from about 7% to 50% as the illumination is changed from a single-mode fully coherent field to that of an azimuthal partially coherent field.

physics.app-ph

Influence of magnetic fields on the performance of spin-orbit torque magnetic random-access memory

Spin-orbit torque magnetic random-access memory (SOT-MRAM) offers high speed, ultrahigh endurance, and compatibility with advanced semiconductor processes, making it a promising candidate for next-generation nonvolatile memory. However, intrinsic bias fields in magnetic tunnel junctions (MTJs), originating from reference-layer stray fields and interlayer coupling, cause asymmetric critical switching currents and increased energy consumption. Existing compensation approaches usually introduce additional magnetic layers into the MTJ stack, which increases fabrication complexity and limits wafer-scale integration. Here, we propose a bias-compensation strategy without modifying the MTJ stack by engineering local stray magnetic fields through magnetic filling materials in vertical interconnect access (VIA) channels during the back-end-of-line process. Micromagnetic simulations show that the proposed magnetic filling layer can provide the required auxiliary field for deterministic switching and significantly suppress write-current asymmetry. By optimizing the MTJ position relative to the magnetic filling structure, the write-current bias ratio is reduced from 21.6% in the conventional design to 1.3%. The approach is also applicable to in-plane magnetic anisotropy SOT-MTJs, reducing the bias ratio from 19.8% to -0.2%. Scaling analysis further demonstrates that the compensation effect remains effective when the device size is reduced to 20% of the original dimension (MTJ diameter approximately 10 nm), indicating its potential for high-density SOT-MRAM integration.

physics.app-ph