arXiv · 2210.16608
Benchmarking between fluid and global models for low-pressure oxygen DC glow discharges
Abstract
This work focuses on the benchmarking between a zero-dimensional (0D) global model (LoKI) and a one-dimensional (1D) radial fluid model for the positive column of oxygen DC glow discharges in a tube of 1 cm inner radius at pressures between 0.5 Torr and 10 Torr. The data used in the two models are the same, so that the difference between the models is reduced to dimensionality. A good agreement is found between the two models on the main discharge parameters, with relative differences below 5%. The agreement on species average number densities, charged and neutral, is slightly worse, with relative differences increasing with pressure from 11% at 0.5 Torr to 57% at 10 Torr. The success of the 0D global model in describing these plasmas through volume averaged quantities decreases with pressure, due to pressure-driven narrowing of radial profiles. Hence, in the studied conditions, we recommend the use of volume-averaged models only in the pressure range up to 10 Torr.
Explore related subjects
Keep this discovery
Pedro Viegas, Tiago Cunha Dias, Chloé Fromentin, Alexander Chukalovsky, Yuri Mankelevich, Olga Proshina, Tatyana Rakhimova, Vasco Guerra, Dmitry Voloshin. 2022-10-29. Benchmarking between fluid and global models for low-pressure oxygen DC glow discharges. https://doi.org/10.1088/1361-6595/acbb9c
Cite the original work for its findings. Save a collection to share your selection of sources.