arXiv · 2306.10731
Physical dealloying for two-phase heat transfer applications: pool boiling case
Abstract
In this work, physical dealloying was explored as a simple and green method to microstructure the surface of commercial brass for pool boiling heat transfer coefficient enhancement. Three samples were dealloyed for 0.5, 1 and 3 hours at 650 C, turning the smooth surface into a porous one with a depth of 175, 200 and 223 um. The boiling experiments carried out in ethanol at 78 C have shown, that the maximum enhancement of heat transfer coefficient between 110 and 150% was achieved for the sample dealloyed for 0.5 h. Longer intervals of dealloying reduce boiling performance, but it is still much higher compared to smooth brass. This simple method can be customized for various thermal management equipment, such as conventional, plate and micro heat exchangers, all types of heat pipes, HVAC equipment etc., where the heat transfer occurs with phase change.
Explore related subjects
Keep this discovery
Artem Nikulin, Yaroslav Grosu, Jean-Luc Dauvergne, Asier Ortuondo, Elena Palomo del Barrio. 2023-06-19. Physical dealloying for two-phase heat transfer applications: pool boiling case. https://doi.org/10.1016/j.icheatmasstransfer.2023.106913
Cite the original work for its findings. Save a collection to share your selection of sources.