SearcharxivSearch

arXiv · 2306.13969

Farthest Streamline Sampling for the Uniform Distribution of Forearm Muscle Fiber Tracts from Diffusion Tensor Imaging

Abstract

Background: Diffusion tensor imaging (DTI) has been used to characterize forearm muscle architecture. Since only uniform sampling is performed for seed points rather than fiber tracts, the tracts may be unevenly distributed in the muscle volume. Purpose: To reconstruct uniformly distributed fiber tracts in human forearm by filtering the tracts from DTI. Assessment: Farthest streamline sampling (FSS) was proposed for filtering and compared with two conventional methods, i.e., two-dimensional sampling and three-dimensional sampling. The uniform coverage performance of the methods was evaluated by streamline coverage (SC) and the coefficient of variation of streamline density (SDCV). Architectural parameters were calculated for 17 forearm muscles. Anatomical correctness was verified by 1. visually assessing the fiber orientation, 2. checking whether the architectural parameters were within physiological ranges, and 3. classifying the architectural types. Results: FSS had the highest SC (0.93+0.04) and the lowest SDCV (0.34+0.06) among the three methods (P<0.05). FSS reduced the sampling of long tracts (10% reduction in fiber length, P<0.05), and the architectural parameters were within physiological ranges (two parameters with P<0.05). The fiber orientation of the tractography was visually consistent with that of the cadaveric specimen. The architectural types of 16 muscles were correctly classified, except for the palmaris longus, which had a linear arrangement of fiber endpoints (R2=0.95+0.02, P<0.001). Data Conclusion: FSS reconstructed more muscle regions and uniformly distributed fiber tracts. The tracts were anatomically correct, indicating the validity of fiber tracts. Key Words: diffusion tensor imaging; forearm muscles; architectural properties

Explore related subjects

Keep this discovery

BibTeXRIS

Yang Li, Shihan Ma, Jiamin Zhao, Qing Li, Xinjun Sheng. 2023-06-24. Farthest Streamline Sampling for the Uniform Distribution of Forearm Muscle Fiber Tracts from Diffusion Tensor Imaging. https://arxiv.org/abs/2306.13969

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV