SearcharxivSearch

arXiv · 2312.14996

Bridging AI and Clinical Practice: Integrating Automated Sleep Scoring Algorithm with Uncertainty-Guided Physician Review

Abstract

Purpose: This study aims to enhance the clinical use of automated sleep-scoring algorithms by incorporating an uncertainty estimation approach to efficiently assist clinicians in the manual review of predicted hypnograms, a necessity due to the notable inter-scorer variability inherent in polysomnography (PSG) databases. Our efforts target the extent of review required to achieve predefined agreement levels, examining both in-domain and out-of-domain data, and considering subjects diagnoses. Patients and methods: Total of 19578 PSGs from 13 open-access databases were used to train U-Sleep, a state-of-the-art sleep-scoring algorithm. We leveraged a comprehensive clinical database of additional 8832 PSGs, covering a full spectrum of ages and sleep-disorders, to refine the U-Sleep, and to evaluate different uncertainty-quantification approaches, including our novel confidence network. The ID data consisted of PSGs scored by over 50 physicians, and the two OOD sets comprised recordings each scored by a unique senior physician. Results: U-Sleep demonstrated robust performance, with Cohen's kappa (K) at 76.2% on ID and 73.8-78.8% on OOD data. The confidence network excelled at identifying uncertain predictions, achieving AUROC scores of 85.7% on ID and 82.5-85.6% on OOD data. Independently of sleep-disorder status, statistical evaluations revealed significant differences in confidence scores between aligning vs discording predictions, and significant correlations of confidence scores with classification performance metrics. To achieve K of at least 90% with physician intervention, examining less than 29.0% of uncertain epochs was required, substantially reducing physicians workload, and facilitating near-perfect agreement.

Explore related subjects

Keep this discovery

BibTeXRIS

Michal Bechny, Giuliana Monachino, Luigi Fiorillo, Julia van der Meer, Markus H. Schmidt, Claudio L. A. Bassetti, Athina Tzovara, Francesca D. Faraci. 2023-12-22. Bridging AI and Clinical Practice: Integrating Automated Sleep Scoring Algorithm with Uncertainty-Guided Physician Review. https://arxiv.org/abs/2312.14996

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG