arXiv · 2312.17548
A new method to measure the unloaded quality factor of superconducting cavities
Abstract
We describe an method that measures the unloaded quality factor $Q_0$, the external quality factor $Q_E$, and the cavity detuning $\Delta\omega$ with a recursive least-squares algorithm. It combines a large number of consecutive measurements to successively improve an estimate of fit parameters that asymptotically converges to the ``real'' values. Exploiting the large amount of data acquired by a digital low-level RF system permits us to reach this asymptotic regime in a moderate time frame of seconds to minutes. Simulations show that the method works both for critically coupled and over-coupled cavities. A new calibration method adresses very tight tolerances of the method on system parameters.
Explore related subjects
Keep this discovery
Volker Ziemann. 2023-12-29. A new method to measure the unloaded quality factor of superconducting cavities. https://doi.org/10.1103/physrevaccelbeams.27.032001
Cite the original work for its findings. Save a collection to share your selection of sources.