SearcharxivSearch

arXiv · 2407.18818

Three-dimensional ultrasound-based online system for automated ovarian follicle measurement

Abstract

Ultrasound follicle tracking is an important part of cycle monitoring. OSIS Ovary (Online System for Image Segmentation for the Ovary) has been conceived aiming to aid the management of the workflow in follicle tracking, one of the most iterative procedures in cycle monitoring during ovarian stimulation. In the present study, we compared OSIS Ovary (as three-dimensional ultrasound-based automated system) with the two-dimensional manual standard measurement method, in order to assess the reliability of the main measurements obtained to track follicle growth during ovarian stimulation cycles, the follicle size and count. Based on the mean follicle diameter and follicle count values obtained, the Pearson/intraclass correlation coefficients were 0.976/0.987 and 0.804/0.889 in >=10mm follicles, 0.989/0.994 and 0.809/0.867 in >=13mm follicles and 0.995/0.997 and 0.791/0.840 in >=16mm follicles. The mean difference (MnD) for the mean diameter and follicle count was, respectively, 0.759/0.161 in >=10mm follicles, 0.486/1.033 in >=13mm follicles and 0.784/0.486 in >=16mm follicles. The upper and lower limits of agreement (ULA and LLA) were 3.641/2.123 and 5.392/3.070 in >=10mm follicles, 3.496/2.522 and 4.285/2.218 in >=13mm follicles, and 3.723/2.153 and 2.432/1.459 in >=16mm follicles. The limits of agreement range (LoAR) were 5.764/8.462 in >=10mm follicles, 6.048/6.503 in >=13mm follicles and 5.876/3.891 in >=16mm follicles. P<0.05 was considered for all calculations. As three-dimensional ultrasound-based automated system in comparison with two-dimensional manual method standard, we found OSIS Ovary as a reliable tool to track follicle growth during ovarian stimulation cycles

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pedro Royo, Elkin Muñoz, José-Enrique Romero, José-Vicente Manjón, Catalina Roig, Carmen Fernández-Delgado, Nuria Muñiz, Antonio Requena, Nicolás Garrido, Juan Antonio García- Velasco, Antonio Pellicer. 2024-07-26. Three-dimensional ultrasound-based online system for automated ovarian follicle measurement. https://arxiv.org/abs/2407.18818

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Adaptive therapy under parametric, structural, and measurement uncertainty

Adaptive therapy has emerged as a promising treatment strategy that exploits within-tumour competition to delay disease progression. Implementation, however, typically relies on indirect measurements of tumour burden and must account for potentially substantial patient heterogeneity. In this work, we capture patient-to-patient variability, parameter uncertainty, and imperfect biomarker measurements with a mathematical and statistical model that we calibrate to clinical prostate cancer data using a Bayesian inference framework. We use the resulting virtual cohort to demonstrate that, within the simple but now well-established Lotka-Volterra-based model, adaptive therapy robustly improves time-to-progression for the subset of patients that are predicted to eventually progress by the model. To account for other risk factors associated with larger tumour volumes, we introduce a new metric based on the risk of metastasis that demonstrates how adaptive therapy may be disadvantageous when sustained tumour burden is also considered. Given the ubiquity of uncertainty in oncology, we then describe several future modelling directions that also capture uncertainty in the temporal evolution of the underlying tumour or biomarker dynamics. Finally, we demonstrate how model misspecification and non-identifiability can lead to unreliable predictions, especially if uncertainty is inadequately captured.

q-bio.TO

Head Impact Characterization and Cellular Response of a Live-neuron cell-integrated Biomechanical Full-body Surrogate Model

In this study, we develop a novel integrated framework that links the impact response with cellular dynamics using a live-neuron cell-integrated biomechanical full-body surrogate model. The impact event is simulated by allowing the surrogate model to fall from controlled seated release angles of 30-degree, 60-degree, and 90-degree. Three vertically stacked cell-culture Petri dishes, each containing live SH-SY5Y neuroblastoma cells, were placed inside the head of a commercially available surrogate model. The dynamic response of the impact event was evaluated using acceleration measurements from six accelerometers, comprising three sensors mounted on the head surface and three embedded in series with the cell stacks, along with kinematic measurements of the fall and deformation of the head model. In parallel, an OpenSim-based modified musculoskeletal model was used to simulate the fall experiment. We found that variation in contact stiffness produced the largest change in the predicted head acceleration in the simulation. When the cellular response and the measured accelerations are compared, oxidative stress and cell viability showed trends consistent with the regional acceleration and angle of fall. At the 90-degree fall, where median peak linear accelerations ranged from 170-258g, and the maximum headform deformation was approximately 9.4 mm, oxidative stress increased to approximately twice that of the control sample. We also quantified the cellular drift of SH-SY5Y cells, which is focal in nature for the 90-degree impact condition. The corresponding fall scenarios were also simulated in OpenSim and a preliminary calibration relationship was developed to compare the kinematic responses of the physical surrogate and musculoskeletal model. Finally, the framework provides a basis for relating experimental surrogate measurements to human head-neck response during impact.

q-bio.TO

History Matters: Damage-Mediated Amplification of Brain Deformation and Injury Risk under Repeated Head Impacts

Computational head models are typically applied to isolated impacts, leaving repeated head loading largely unexplored. An Ogden-Roxburgh Mullins damage formulation was implemented in a high-fidelity finite element head model to represent loading-history-dependent softening during cyclic brain-tissue deformation. Repeated-loading histories derived from mixed martial arts head-impact data were applied and compared with damage-free hyperelastic (HE) and linear visco-hyperelastic (LVHE) model variants. Under five identical single-axis cycles, Mullins-type softening progressively increased strain and strain rate metrics relative to the HE model. Mullins-based injury probabilities progressively exceeded strain-based HE predictions and diverged from unchanged kinematics-based predictions, indicating that neglecting prior softening may underestimate injury risk. In a randomized twenty-cycle multiaxial sequence, cycles of similar kinematic intensity produced different deformation and injury-risk estimates depending on prior softening. HE and LVHE models predicted higher injury probabilities initially, whereas the Mullins-based model produced the largest later-cycle estimates and highest probability of at least one injury over the sequence. Regional amplification depended on loading direction and prior softening, with no direction-independent trend among brain substructures. Gyral elements exhibited higher cumulative maximum principal strain than sulcal elements, which showed greater amplification relative to initial responses. These findings demonstrate that short-term damage-mediated softening can substantially amplify tissue deformation and injury-risk estimates beyond damage-free head models under the same loading histories. Further experimental characterization of cyclic brain-tissue softening is needed to improve models of repeated head loading and traumatic brain injury.

q-bio.TO