SearcharxivSearch

arXiv · 2409.14250

A prospectus on the surface metrology of seborrheic keratoses

Abstract

Background: Human skin texture has yet to be quantified for diagnostic purposes. Here, the surface metrology of seborrheic keratoses is investigated with an optical profiler. Materials and Methods: Dermatologic specimens of 7 cadavers were prepared. Specimens were molded with polyvinyl siloxane and casts prepared with resin, which were scanned using a 3D white light optical profiler. Each scan produced 48 variables, categorized into 3 groups for each location: control, lesion center, and lesion edge. Images of the histopathology slides for suspected seborrheic keratoses were reviewed by a dermatopathologist. Results: The parameters under investigation included border versus center of keratoses, age, sex, lesion location, degree of sun exposure, and cause of death. Although some parameters differ between individuals and age groups, the majority of differences identified between the roughness parameters measured are a result of sex, sun exposure, and histological diagnosis, listed in order of increasing importance. Histological diagnosis provided the most significant, definitive number of individual measurements of areas of roughness in seborrheic keratoses in comparison to other parts of the skin (regardless if those were controls or a different pigmented lesion aside from seborrheic keratoses). Conclusions: This study demonstrates that there are quantifiable patterns of surface textures that can be compared between keratotic and standard normal skin surfaces. These findings suggest this method has the potential to be applied as a noninvasive adjunct to current methods of dermatological diagnosis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nicole Werpachowski, Juliette Nutovits, Therese Limbana, John Goncalves, Alina Bridges, Brian Lee Beatty. 2024-09-21. A prospectus on the surface metrology of seborrheic keratoses. https://arxiv.org/abs/2409.14250

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Adaptive therapy under parametric, structural, and measurement uncertainty

Adaptive therapy has emerged as a promising treatment strategy that exploits within-tumour competition to delay disease progression. Implementation, however, typically relies on indirect measurements of tumour burden and must account for potentially substantial patient heterogeneity. In this work, we capture patient-to-patient variability, parameter uncertainty, and imperfect biomarker measurements with a mathematical and statistical model that we calibrate to clinical prostate cancer data using a Bayesian inference framework. We use the resulting virtual cohort to demonstrate that, within the simple but now well-established Lotka-Volterra-based model, adaptive therapy robustly improves time-to-progression for the subset of patients that are predicted to eventually progress by the model. To account for other risk factors associated with larger tumour volumes, we introduce a new metric based on the risk of metastasis that demonstrates how adaptive therapy may be disadvantageous when sustained tumour burden is also considered. Given the ubiquity of uncertainty in oncology, we then describe several future modelling directions that also capture uncertainty in the temporal evolution of the underlying tumour or biomarker dynamics. Finally, we demonstrate how model misspecification and non-identifiability can lead to unreliable predictions, especially if uncertainty is inadequately captured.

q-bio.TO

Head Impact Characterization and Cellular Response of a Live-neuron cell-integrated Biomechanical Full-body Surrogate Model

In this study, we develop a novel integrated framework that links the impact response with cellular dynamics using a live-neuron cell-integrated biomechanical full-body surrogate model. The impact event is simulated by allowing the surrogate model to fall from controlled seated release angles of 30-degree, 60-degree, and 90-degree. Three vertically stacked cell-culture Petri dishes, each containing live SH-SY5Y neuroblastoma cells, were placed inside the head of a commercially available surrogate model. The dynamic response of the impact event was evaluated using acceleration measurements from six accelerometers, comprising three sensors mounted on the head surface and three embedded in series with the cell stacks, along with kinematic measurements of the fall and deformation of the head model. In parallel, an OpenSim-based modified musculoskeletal model was used to simulate the fall experiment. We found that variation in contact stiffness produced the largest change in the predicted head acceleration in the simulation. When the cellular response and the measured accelerations are compared, oxidative stress and cell viability showed trends consistent with the regional acceleration and angle of fall. At the 90-degree fall, where median peak linear accelerations ranged from 170-258g, and the maximum headform deformation was approximately 9.4 mm, oxidative stress increased to approximately twice that of the control sample. We also quantified the cellular drift of SH-SY5Y cells, which is focal in nature for the 90-degree impact condition. The corresponding fall scenarios were also simulated in OpenSim and a preliminary calibration relationship was developed to compare the kinematic responses of the physical surrogate and musculoskeletal model. Finally, the framework provides a basis for relating experimental surrogate measurements to human head-neck response during impact.

q-bio.TO

History Matters: Damage-Mediated Amplification of Brain Deformation and Injury Risk under Repeated Head Impacts

Computational head models are typically applied to isolated impacts, leaving repeated head loading largely unexplored. An Ogden-Roxburgh Mullins damage formulation was implemented in a high-fidelity finite element head model to represent loading-history-dependent softening during cyclic brain-tissue deformation. Repeated-loading histories derived from mixed martial arts head-impact data were applied and compared with damage-free hyperelastic (HE) and linear visco-hyperelastic (LVHE) model variants. Under five identical single-axis cycles, Mullins-type softening progressively increased strain and strain rate metrics relative to the HE model. Mullins-based injury probabilities progressively exceeded strain-based HE predictions and diverged from unchanged kinematics-based predictions, indicating that neglecting prior softening may underestimate injury risk. In a randomized twenty-cycle multiaxial sequence, cycles of similar kinematic intensity produced different deformation and injury-risk estimates depending on prior softening. HE and LVHE models predicted higher injury probabilities initially, whereas the Mullins-based model produced the largest later-cycle estimates and highest probability of at least one injury over the sequence. Regional amplification depended on loading direction and prior softening, with no direction-independent trend among brain substructures. Gyral elements exhibited higher cumulative maximum principal strain than sulcal elements, which showed greater amplification relative to initial responses. These findings demonstrate that short-term damage-mediated softening can substantially amplify tissue deformation and injury-risk estimates beyond damage-free head models under the same loading histories. Further experimental characterization of cyclic brain-tissue softening is needed to improve models of repeated head loading and traumatic brain injury.

q-bio.TO