SearcharxivSearch

arXiv · 2503.17664

CardioTabNet: A Novel Hybrid Transformer Model for Heart Disease Prediction using Tabular Medical Data

Abstract

The early detection and prediction of cardiovascular diseases are crucial for reducing the severe morbidity and mortality associated with these conditions worldwide. A multi-headed self-attention mechanism, widely used in natural language processing (NLP), is operated by Transformers to understand feature interactions in feature spaces. However, the relationships between various features within biological systems remain ambiguous in these spaces, highlighting the necessity of early detection and prediction of cardiovascular diseases to reduce the severe morbidity and mortality with these conditions worldwide. We handle this issue with CardioTabNet, which exploits the strength of tab transformer to extract feature space which carries strong understanding of clinical cardiovascular data and its feature ranking. As a result, performance of downstream classical models significantly showed outstanding result. Our study utilizes the open-source dataset for heart disease prediction with 1190 instances and 11 features. In total, 11 features are divided into numerical (age, resting blood pressure, cholesterol, maximum heart rate, old peak, weight, and fasting blood sugar) and categorical (resting ECG, exercise angina, and ST slope). Tab transformer was used to extract important features and ranked them using random forest (RF) feature ranking algorithm. Ten machine-learning models were used to predict heart disease using selected features. After extracting high-quality features, the top downstream model (a hyper-tuned ExtraTree classifier) achieved an average accuracy rate of 94.1% and an average Area Under Curve (AUC) of 95.0%. Furthermore, a nomogram analysis was conducted to evaluate the model's effectiveness in cardiovascular risk assessment. A benchmarking study was conducted using state-of-the-art models to evaluate our transformer-driven framework.

Explore related subjects

Keep this discovery

BibTeXRIS

Md. Shaheenur Islam Sumon, Md. Sakib Bin Islam, Md. Sohanur Rahman, Md. Sakib Abrar Hossain, Amith Khandakar, Anwarul Hasan, M Murugappan, Muhammad E. H. Chowdhury. 2025-03-22. CardioTabNet: A Novel Hybrid Transformer Model for Heart Disease Prediction using Tabular Medical Data. https://arxiv.org/abs/2503.17664

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG