SearcharxivSearch

arXiv · 2506.07092

Patient Similarity Computation for Clinical Decision Support: An Efficient Use of Data Transformation, Combining Static and Time Series Data

Abstract

Patient similarity computation (PSC) is a fundamental problem in healthcare informatics. The aim of the patient similarity computation is to measure the similarity among patients according to their historical clinical records, which helps to improve clinical decision support. This paper presents a novel distributed patient similarity computation (DPSC) technique based on data transformation (DT) methods, utilizing an effective combination of time series and static data. Time series data are sensor-collected patients' information, including metrics like heart rate, blood pressure, Oxygen saturation, respiration, etc. The static data are mainly patient background and demographic data, including age, weight, height, gender, etc. Static data has been used for clustering the patients. Before feeding the static data to the machine learning model adaptive Weight-of-Evidence (aWOE) and Z-score data transformation (DT) methods have been performed, which improve the prediction performances. In aWOE-based patient similarity models, sensitive patient information has been processed using aWOE which preserves the data privacy of the trained models. We used the Dynamic Time Warping (DTW) approach, which is robust and very popular, for time series similarity. However, DTW is not suitable for big data due to the significant computational run-time. To overcome this problem, distributed DTW computation is used in this study. For Coronary Artery Disease, our DT based approach boosts prediction performance by as much as 11.4%, 10.20%, and 12.6% in terms of AUC, accuracy, and F-measure, respectively. In the case of Congestive Heart Failure (CHF), our proposed method achieves performance enhancement up to 15.9%, 10.5%, and 21.9% for the same measures, respectively. The proposed method reduces the computation time by as high as 40%.

Explore related subjects

Keep this discovery

BibTeXRIS

Joydeb Kumar Sana, Mohammad M. Masud, M Sohel Rahman, M Saifur Rahman. 2025-06-08. Patient Similarity Computation for Clinical Decision Support: An Efficient Use of Data Transformation, Combining Static and Time Series Data. https://arxiv.org/abs/2506.07092

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG