SearcharxivSearch

arXiv · 2506.14844

Improving Prostate Gland Segmentation Using Transformer based Architectures

Abstract

Inter reader variability and cross site domain shift challenge the automatic segmentation of prostate anatomy using T2 weighted MRI images. This study investigates whether transformer models can retain precision amid such heterogeneity. We compare the performance of UNETR and SwinUNETR in prostate gland segmentation against our previous 3D UNet model [1], based on 546 MRI (T2weighted) volumes annotated by two independent experts. Three training strategies were analyzed: single cohort dataset, 5 fold cross validated mixed cohort, and gland size based dataset. Hyperparameters were tuned by Optuna. The test set, from an independent population of readers, served as the evaluation endpoint (Dice Similarity Coefficient). In single reader training, SwinUNETR achieved an average dice score of 0.816 for Reader#1 and 0.860 for Reader#2, while UNETR scored 0.8 and 0.833 for Readers #1 and #2, respectively, compared to the baseline UNets 0.825 for Reader #1 and 0.851 for Reader #2. SwinUNETR had an average dice score of 0.8583 for Reader#1 and 0.867 for Reader#2 in cross-validated mixed training. For the gland size-based dataset, SwinUNETR achieved an average dice score of 0.902 for Reader#1 subset and 0.894 for Reader#2, using the five-fold mixed training strategy (Reader#1, n=53; Reader#2, n=87) at larger gland size-based subsets, where UNETR performed poorly. Our findings demonstrate that global and shifted-window self-attention effectively reduces label noise and class imbalance sensitivity, resulting in improvements in the Dice score over CNNs by up to five points while maintaining computational efficiency. This contributes to the high robustness of SwinUNETR for clinical deployment.

Explore related subjects

Keep this discovery

BibTeXRIS

Shatha Abudalou, Jung Choi, Yasin Yilmaz, Yoganand Balagurunathan. 2025-06-16. Improving Prostate Gland Segmentation Using Transformer based Architectures. https://arxiv.org/abs/2506.14844

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV