SearcharxivSearch

arXiv · 2507.14308

Self-Supervised Joint Reconstruction and Denoising of T2-Weighted PROPELLER MRI of the Lungs at 0.55T

Abstract

Purpose: This study aims to improve 0.55T T2-weighted PROPELLER lung MRI through a self-supervised joint reconstruction and denoising model. Methods: T2-weighted 0.55T lung MRI dataset including 44 patients with previous covid infection were used. A self-supervised learning framework was developed, where each blade of the PROPELLER acquisition was split along the readout direction into two partitions. One subset trains the unrolled reconstruction network, while the other subset is used for loss calculation, enabling self-supervised training without clean targets and leveraging matched noise statistics for denoising. For comparison, Marchenko-Pastur Principal Component Analysis (MPPCA) was performed along the coil dimension, followed by conventional parallel imaging reconstruction. The quality of the reconstructed lung MRI was assessed visually by two experienced radiologists independently. Results: The proposed self-supervised model improved the clarity and structural integrity of the lung images. For cases with available CT scans, the reconstructed images demonstrated strong alignment with corresponding CT images. Additionally, the proposed model enables further scan time reduction by requiring only half the number of blades. Reader evaluations confirmed that the proposed method outperformed MPPCA-denoised images across all categories (Wilcoxon signed-rank test, p<0.001), with moderate inter-reader agreement (weighted Cohen's kappa=0.55; percentage of exact and within +/-1 point agreement=91%). Conclusion: By leveraging intrinsic structural redundancies between two disjoint splits of k-space subsets, the proposed self-supervised learning model effectively reconstructs the image while suppressing the noise for 0.55T T2-weighted lung MRI with PROPELLER sampling.

Explore related subjects

Keep this discovery

BibTeXRIS

Jingjia Chen, Haoyang Pei, Christoph Maier, Mary Bruno, Qiuting Wen, Seon-Hi Shin, William Moore, Hersh Chandarana, Li Feng. 2025-07-18. Self-Supervised Joint Reconstruction and Denoising of T2-Weighted PROPELLER MRI of the Lungs at 0.55T. https://doi.org/10.1002/mrm.70224

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV