Temperature Optimisation in Data Centres

Abstract

Raising server inlet temperatures tends to increase the server power consumption due to heightened server fan activity needed to compensate for the warmer air, and to decrease cooling infrastructure power consumption due to less intense and possibly less frequent chiller activity. Relying on primary data from two data centres of a colocation provider in Switzerland, this study succeeds in confirming and quantifying the first effect: In the upper half of the ASHRAE recommended temperature range and slightly above it, i.e., between 23 - 30 {\deg}C, the server power consumption correlated positively with the temperature, with a server room-wide temperature sensitivity of 0.35 - 0.5 %/{\deg}C. Based on the available data and due to ambivalent results, the study did not succeed in answering which effect is stronger for the entire data centre: the increase in server consumption or the savings in cooling consumption. Whether raising inlet temperatures beyond the ASHRAE upper limit (i.e., 27 {\deg}C) yields additional overall benefits thus remains an open question that would be best addressed through controlled experiments. A few pieces of evidence indicate nevertheless that the upper part of the current ASHRAE recommendation (i.e., around 25 - 27 {\deg}C) might be the current sweet spot for colocation DCs. The widely used power usage effectiveness (PUE) metric is not at all useful in this context. For practical reasons but semantically wrong, the server fan power consumption is included in the consumption of servers (and thus, of the IT infrastructure) and is thus on the wrong side of the PUE fraction. An inlet temperature raise, which will lead to increased fan consumption, will thus always yield a PUE decrease, irrespective of what happens to the overall data centre power consumption.

Explore related subjects

Keep this discovery

BibTeXRIS

Vlad C. Coroamă. 2025-09-30. Temperature Optimisation in Data Centres. https://arxiv.org/abs/2509.26163

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Circular Economy Synergies and Trade-offs in Data Centres

This report analyses data centre (DC) sustainability and circularity, revealing existing synergies and trade-offs: The PUE is too coarse, mixing cooling and power provisioning. It wrongly attributes server fan consumption and transformation losses to IT energy. It does not measure compute but infrastructure efficiency, which is already outstanding. Compute energy, however, is exploding. Better energy metrics for DCs would thus cover i) compute efficiency, ii) transformation efficiency, and iii) cooling overhead. Trade-offs exist between cooling energy and water as well as on-site and upstream water: Consuming water on-site lowers the cooling energy, which also lowers the water consumed upstream in power generation. For 'wet' electricity, there is little competition: It is worth spending more on-site energy to save both electricity and related upstream water. For 'dry' electricity, there is a trade-off. Waste heat recovery brings energy circularity but has limited uses and is not the same energy quality, a fact not reflected by current metrics. A better metric would consider the avoided energy through heat recovery instead of the amount recovered. Material circularity can be achieved by interpreting the 9R framework in the context of DCs. Circularity-enhancing measures can be categorised into product design, process design and business models, choice of materials, and operating conditions. Together, they have effects across all circularity levels. The relation between DCs and the power grid is complex. Modern DCs present new challenges for the grid. Mitigation includes battery storage and onsite generation. These measures have, in turn, further consequences, both beneficial and detrimental. They can offer grid flexibility as well as innovations in the field of energy. But they also bring noise, pollution, and GHGs, and compete with the energy sector for resources.

cs.OH

Digital Twin Modeling of a Highly Automated Agricultural Tractor

In efforts to increase research efficiency and availability, a digital twin of our research tractor (AMX G-trac) is created, focusing especially on the CAN communication for data reading and actuation command following the ISOBUS protocol. Mevea Simulation Software is utilized as the foundation, providing the kinematic model and visuals, while Python is used to read and write CAN messages over a Kvaser CanKing virtual CAN channel. Various performance tests involving straight line and turning behavior are performed in both the digital twin simulation and in the real world to measure similarity. Results indicate that the Mevea model behaves very comparable in its lateral dynamics, often within 5-10 percent, but requires better data to fully capture the longitudinal aspects like acceleration. The final model described in this paper sets the table for a second iteration to include more tractor functions such as hydraulics and tractor-implement dynamics.

cs.OH

Risk-based Design for Sustainability in Cloud Systems: Insights from an Experts' Survey

Cloud Systems' Sustainability is critical in Cloud Computing, especially with the growing demand in many industries. Sustainability risks in Cloud Computing can be tricky, mostly because of system complexity and their impact on performance. Thus, this research focuses on Risk-based design (RBD) and how it can support the early identification of possible risks for Cloud System Sustainability, as well as respective mitigation strategies of each risk. In order to successfully identify risks of Cloud System Sustainability, an Expert Survey is conducted including experts with different roles from different industries, to identify possible sustainability risks of a Cloud System on all different levels. Thematic analysis of the responses resulted in a categorization of risks, as well as in the identification of mitigation strategies and factors affecting each risk. Such findings can be helpful for researchers and practitioners that utilize RBD when building sustainable Cloud systems.

cs.OH