SearcharxivSearch

arXiv · 2510.03372

Real-time nonlinear inversion of magnetic resonance elastography with operator learning

Abstract

$\textbf{Purpose:}$ To develop and evaluate an operator learning framework for nonlinear inversion (NLI) of brain magnetic resonance elastography (MRE) data, which enables real-time inversion of elastograms with comparable spatial accuracy to NLI. $\textbf{Materials and Methods:}$ In this retrospective study, 3D MRE data from 61 individuals (mean age, 37.4 years; 34 female) were used for development of the framework. A predictive deep operator learning framework (oNLI) was trained using 10-fold cross-validation, with the complex curl of the measured displacement field as inputs and NLI-derived reference elastograms as outputs. A structural prior mechanism, analogous to Soft Prior Regularization in the MRE literature, was incorporated to improve spatial accuracy. Subject-level evaluation metrics included Pearson's correlation coefficient, absolute relative error, and structural similarity index measure between predicted and reference elastograms across brain regions of different sizes to understand accuracy. Statistical analyses included paired t-tests comparing the proposed oNLI variants to the convolutional neural network baselines. $\textbf{Results:}$ Whole brain absolute percent error was 8.4 $\pm$ 0.5 ($\mu'$) and 10.0 $\pm$ 0.7 ($\mu''$) for oNLI and 15.8 $\pm$ 0.8 ($\mu'$) and 26.1 $\pm$ 1.1 ($\mu''$) for CNNs. Additionally, oNLI outperformed convolutional architectures as per Pearson's correlation coefficient, $r$, in the whole brain and across all subregions for both the storage modulus and loss modulus (p < 0.05). $\textbf{Conclusion:}$ The oNLI framework enables real-time MRE inversion (30,000x speedup), outperforming CNN-based approaches and maintaining the fine-grained spatial accuracy achievable with NLI in the brain.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Juampablo E. Heras Rivera, Caitlin M. Neher, Mehmet Kurt. 2025-10-03. Real-time nonlinear inversion of magnetic resonance elastography with operator learning. https://arxiv.org/abs/2510.03372

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

eess.IV

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

eess.IV

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

eess.IV