SearcharxivSearch

arXiv · 2511.04207

Interstitial dual-mode ultrasound with a 3-mm MR-compatible catheter for image-guided HIFU and directional in-vitro tissue ablations

Abstract

Current interstitial techniques of tumor ablation face challenges that ultrasound technologies could meet. The ablation radius and directionality of the ultrasound beam could improve the efficiency and precision. Here, a 9gauge MR-compatible dual-mode ultrasound catheter prototype was experimentally evaluated for Ultrasound Imageguided High Intensity Focused Ultrasound (USgHIFU) conformal ablations. The prototype consisted of 64 piezocomposite linear array elements and was driven by an open research programmable dual-mode ultrasound platform. After verifying the US-image guidance capabilities of the prototype, the HIFU output performances (dynamic focusing and HIFU intensities) were quantitatively characterized, together with the associated 3D HIFU-induced thermal heating in tissue phantoms (using MR thermometry). Finally, the ability to produce robustly HIFU-induced thermal ablations in in-vitro liver was studied experimentally and compared to numerical modeling. Investigations of several HIFU dynamic focusing allowed overcoming the challenges of miniaturizing the device: mono-focal focusing maximized deep energy deposition, while multi-focal strategies eliminated grating lobes. The linear-array design of the prototype made it possible to produce interstitial ultrasound images of tissue and tumor mimics in situ. Multi-focal pressure fields were generated without grating lobes and transducer surface intensities reached up to Isapa =14 W$\bullet$cm -2 . Seventeen elementary thermal ablations were performed in vitro. Rotation of the catheter proved the directionality of ablation, sparing non-targeted tissue. This experimental proof of concept demonstrates the feasibility of treating volumes comparable to those of primary solid tumors with a miniaturized USgHIFU catheter whose dimensions are close to those of tools traditionally used in interventional radiology, while offering new functionalities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thomas Biscaldi, Romain l'Huillier, Laurent Milot, W Apoutou N'Djin. 2025-11-06. Interstitial dual-mode ultrasound with a 3-mm MR-compatible catheter for image-guided HIFU and directional in-vitro tissue ablations. https://arxiv.org/abs/2511.04207

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Projection Angles of Projectiles in Sports: Qualitative Assessment of the Effects of Aerodynamic Forces or Run-Up

We examine two major factors that influence the optimum projection angle: aerodynamic forces and the effect of run-up. With respect to aerodynamics, we consider not only the drag but also the lift generated by spin during flight. By linearizing the equations of motion that include these forces, we derive perturbation solutions with respect to drag and lift coefficients and clarify their qualitative effects. The results show that both drag and lift reduce the optimum projection angle, with the latter exerting a stronger influence. To investigate the effect of run-up, we use an extended projection model in which the initial speed depends on the initial angle. Analysis of this model reveals that a stronger run-up increases the relative projection angle but decreases the launch angle observed from the ground. These findings provide a mechanical explanation for the release angle in shot put and the takeoff angle in long jump. The present study establishes a simple theoretical framework for clarifying the respective roles of aerodynamic and run-up effects in determining the optimum projection angles in sports.

physics.class-ph

Dunkl-Based Modeling of Vibrational Modes in Lightweight Elastic Beams

Optimizing slender elastic structures for renewable energy applications requires non-classical continuum formulations capable of accounting for spatial micro-interactions without sacrificing analytical tractability. Here, we extend beam vibration mechanics by replacing standard spatial derivatives with the Dunkl differential operator. This modification introduces a reflection-coupled mathematical structure that accounts for spatial parity effects across the beam domain. We formulate the governing dynamic equations into a generalized eigenvalue problem and derive exact analytical expressions for modal characteristics under standard boundary conditions. The classical limit confirms exact convergence to classical Euler-Bernoulli formulations. Parametric analyses reveal that the Dunkl parameter acts as a reflection-induced modulation parameter, significantly shifting natural frequencies and altering the modal characteristics of higher modes. These results provide an analytical baseline for dynamic optimization in lightweight structural components.

physics.class-ph

A purely mechanical system realizing a Coulomb-like interaction

We solve in closed form a one-dimensional relativistic system: two masses interacting only through elastic collisions with a massless mediator bouncing between them. Momenta, times, and positions are hyperbolic functions of the collision index. The mediator energy, interpreted as the pair's effective potential, obeys an exact discrete Coulomb law, $V\propto 1/r$, with a Lorentz-invariant action as coupling. A massive Newtonian mediator instead transmits a $1/r^{3}$ force; one adiabatic invariant traces both laws to the mediator's dispersion relation. Continued to negative mediator energy, the closed forms turn trigonometric, binding a one-dimensional mechanical analog of the Coulomb atom.

physics.class-ph