SearcharxivSearch

arXiv · 2603.14719

Multimodal Deep Learning for Early Prediction of Patient Deterioration in the ICU: Integrating Time-Series EHR Data with Clinical Notes

Abstract

Early identification of patients at risk for clinical deterioration in the intensive care unit (ICU) remains a critical challenge. Delayed recognition of impending adverse events, including mortality, vasopressor initiation, and mechanical ventilation, contributes to preventable morbidity and mortality. We present a multimodal deep learning approach that combines structured time-series data (vital signs and laboratory values) with unstructured clinical notes to predict patient deterioration within 24 hours. Using the MIMIC-IV database, we constructed a cohort of 74,822 ICU stays and generated 5.7 million hourly prediction samples. Our architecture employs a bidirectional LSTM encoder for temporal patterns in physiologic data and ClinicalBERT embeddings for clinical notes, fused through a cross-modal attention mechanism. We also present a systematic review of existing approaches to ICU deterioration prediction, identifying 31 studies published between 2015 and 2024. Most existing models rely solely on structured data and achieve area under the curve (AUC) values between 0.70 and 0.85. Studies incorporating clinical notes remain rare but show promise for capturing information not present in structured fields. Our multimodal model achieves a test AUROC of 0.7857 and AUPRC of 0.1908 on 823,641 held-out samples, with a validation-to-test gap of only 0.6 percentage points. Ablation analysis validates the multimodal approach: clinical notes improve AUROC by 2.5 percentage points and AUPRC by 39.2% relative to a structured-only baseline, while deep learning models consistently outperform classical baselines (XGBoost AUROC: 0.7486, logistic regression: 0.7171). This work contributes both a thorough review of the field and a reproducible multimodal framework for clinical deterioration prediction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Binesh Sadanandan. 2026-03-16. Multimodal Deep Learning for Early Prediction of Patient Deterioration in the ICU: Integrating Time-Series EHR Data with Clinical Notes. https://arxiv.org/abs/2603.14719

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG