SearcharxivSearch

arXiv · 2605.19191

Open-source segmentation and biometry dataset using spectrally-multiplexed whole-eye optical coherence tomography

Abstract

Whole-eye optical coherence tomography (WEOCT) has emerged as a transformative imaging modality capable of simultaneously capturing the anterior and posterior segments of the human eye. WEOCT enables comprehensive ocular biometry, which is critical for a wide range of clinical and research applications-from intraocular lens power calculation, myopia progression monitoring, and refractive surgery planning to the precise measurement of the visual and optical axes and the generation of personalized eye models for eye tracking in virtual, augmented and mixed reality(VR/AR/MR). However, existing WEOCT systems often face trade-offs between signal-to-noise ratio, imaging speed, and the ability to capture dynamic processes without motion artifacts. To address these limitations, we present a novel spectrally-multiplexed WEOCT system that utilizes two synchronized 200 kHz swept sources at 1310 nm and 1060 nm. Coupled with an automated end-to-end processing pipeline involving deep learning-based surface segmentation, 3D distortion correction, surface fitting and ray-tracing refraction correction, our system enables anatomically accurate 3D reconstruction of the segmented ocular layers. Through a 300+ participant user study and comprehensive phantom studies, we demonstrate that our system can provide simultaneous accurate measurements of cornea topography and 3D pupil center. While labeled retinal OCT data is abundantly available in open-source repositories, labeled B-scan or volumetric anterior segment data remains significantly limited. Consequently, research groups working in related domains must often acquire their own data using custom imaging systems. To help bridge this gap, we are releasing as open-source a comprehensive dataset comprising 6,621 processed volumes from 276 unique participants with corresponding segmentation and calibrated 3D anterior point clouds.

Explore related subjects

Keep this discovery

BibTeXRIS

Ruobing Qian, Catherine Fromm, Pushkar Anand, Kyle Johnson, Zach Willms, Yimin Ding, Weihan Zhang, Ali Behrooz, Mohamed El-Haddad. 2026-05-18. Open-source segmentation and biometry dataset using spectrally-multiplexed whole-eye optical coherence tomography. https://arxiv.org/abs/2605.19191

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Two-step high-accuracy microwave frequency measurement and time-frequency analysis based on optical frequency combs

Broadband microwave frequency measurement and time-frequency analysis are crucial for applications such as electronic warfare. However, when it comes to ultra wideband signal analysis, traditional electronic methods have high analysis accuracy, but intrinsic electronic bottlenecks limit their real-time analysis. Here, we propose and experimentally demonstrate a two-step microwave frequency measurement and time-frequency analysis method based on optical frequency combs. The system first performs coarse frequency localization over the 0-40 GHz range using stimulated-Brillouin-scattering-assisted frequency-to-time mapping (FTTM) and dual-comb channelized reception. The dual-comb is then reapplied for downconverting the signal under test, followed by digital signal processing to achieve high-accuracy unambiguous frequency extraction. Experimental results show that the system achieves mean single-tone frequency measurement errors of less than 10 kHz over 0-40 GHz. We further experimentally measure multi-tone, linearly frequency-modulated, and V-shaped frequency-modulated signals, demonstrating the proposed method's capability for analyzing complex signals.

physics.optics

A Two-Mirror Faceted Projection System for EUV Lithography

We propose an all-reflective two-mirror projection system for extreme ultraviolet (EUV) lithography operating at exposure wavelengths of $13.5$~nm (Mo/Si) and $11.2$~nm (Ru/Be), delivering a fourfold ($4\times$) demagnification of the periodic mask pattern at a numerical aperture approaching unity ($\mathrm{NA}_{\max} \approx 0.993$). In contrast to conventional EUV projection objectives that incorporate 6--10 aspheric mirrors with an overall optical throughput of less than $15\%$, the proposed design redirects each accepted discrete spatial diffraction order scattered by the mask onto the wafer via a dedicated pair of planar mirror facets. The number of reflections is strictly fixed at two for all accepted orders, retaining $50$--$60\%$ of the power leaving the mask in each accepted order. We derive a spatial geometry providing rigorous optical path length equalization across all diffraction orders, thereby removing order-dependent propagation phase shifts. Individually optimized 30-bilayer Bragg multilayer coatings are designed for each facet using the transfer matrix method combined with global evolutionary optimization algorithms. The architecture is generalized to a three-dimensional vector formulation with a two-dimensionally periodic mask. Utilizing inverse lithography technology, Fourier parameterization, and a differentiable electromagnetic modal waveguide solver, we solve the synthesis problem for binary absorber masks (La absorber on a Ru/Be/Sr multilayer mirror). We demonstrate simulated aerial images of sub-10-nm features on the wafer (isolated peaks with a full width at half maximum (FWHM) of approximately $5.4$~nm and line pairs with a critical dimension of $6$~nm) and find that the two peaks remain resolved for the tested wafer defocus values from $0$ to $5$~nm along the $z$-axis.

physics.optics

Antimony for broadband nanophotonics across the ultraviolet, visible and infrared

Semimetal elemental antimony (Sb) nanostructures show great potential for applications where nanophotonic properties play a key role, such as phase-change optical memories, non-linear optical elements, photothermal therapy agents, photodetectors and photocatalysts. However, designing advanced Sb-based photonic devices critically requires an accurate and reliable knowledge of the optical response of bulk and nanoscale Sb. Herein, we report for the first time a fully consistent and accurately measured dielectric function for Sb nanoscale films in a wide spectral range from the ultraviolet to the far infrared (4 - 0.04 eV, i.e. ~ 0.3 - 30 $\mu$m), surpassing previous reports that explored a limited spectral range. It is found that the Sb spectral response is driven exclusively by giant interband transitions in the visible up to mid infrared (4 - 0.4 eV, i.e. ~ 0.3 - 3 $\mu$m), and that their contribution dominates over that of free carriers down to 0.12 eV (i.e. ~ 10 $\mu$m). Such spectral response enables Sb nanostructures to display spectrally selective and tunable nanophotonic resonances. First, we showcase interband plasmonic resonances in the visible-to-near infrared for Sb nanogratings. Second, we report giant refractive index dielectric resonances in the mid infrared for nanostructured Sb/dielectric/metal resonant cavities. These findings open a pathway to optimized planar Sb nanoscale designs enabling a tailored light-matter interaction, which will be useful for integrated data, telecom, medical, optoelectronic and energy conversion devices operating in a broad spectral range.

physics.optics