SearcharxivSearch

arXiv · 2606.12658

Physics-Informed Neural Networks for Chemotherapy Pharmacokinetics: Benchmarking the Clinical Estimator and Exposing Parameter Identifiability

Abstract

Physics-Informed Neural Networks (PINNs) are an attractive tool for partial-observation problems in biology, where the governing dynamics are known but some compartments cannot be measured. Chemotherapy pharmacokinetics (PK) is a clean instance: drug concentration in plasma is routinely measured, but concentration in tissue -- which determines tumour kill and off-target toxicity -- is not. We benchmark a PINN against the standard clinical baseline (nonlinear least-squares on the analytical biexponential plasma solution, hereafter NLS) and a physics-agnostic neural baseline (a data-only MLP) on two PK problems. On the linear two-compartment problem, NLS is near-optimal; the PINN matches it to within a small constant factor while also producing the tissue curve in a single training pass, whereas the data-only MLP fails on tissue by roughly 10x. On a Michaelis-Menten extension (saturable elimination), the biexponential closed form no longer exists, so NLS is mis-specified and silently returns meaningless rate constants. The PINN instead exposes a deeper fact: the Michaelis-Menten two-compartment model is non-identifiable from plasma alone, and the PINN reports this honestly by converging to a basin with k12 -> 0. Adding two sparse tissue observations largely resolves identifiability: across five seeds the PINN recovers k21 to within 1% of truth and Vmax, Km to within one standard-deviation bar, while k12 moves in the correct direction (0.02 -> 0.82) but remains ~2 sigma below truth -- a recovery the closed-form NLS estimator cannot attempt at all, because its biexponential ansatz describes only plasma. Our claim is not that PINNs beat NLS. It is that PINNs offer a uniform recipe that ties the textbook estimator on the textbook problem, exposes structural identifiability that the textbook estimator hides, and absorbs heterogeneous measurements within a single loss.

Explore related subjects

Keep this discovery

BibTeXRIS

Riya Bisht, Dhruv Agarwal. 2026-06-10. Physics-Informed Neural Networks for Chemotherapy Pharmacokinetics: Benchmarking the Clinical Estimator and Exposing Parameter Identifiability. https://arxiv.org/abs/2606.12658

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG