SearcharxivSearch

arXiv · 2607.25288

When Does Deep Representation Learning Help Single-Cell Clustering? A Sensitivity-Aware Diagnostic Benchmark for Biomedical AI Pipelines

Abstract

Single-cell ribonucleic acid sequencing (scRNA-seq) is a foundational technology for precision-medicine workflows that contribute to United Nations Sustainable Development Goal 3 on Good Health and Well-being, and unsupervised clustering is the analytical step that turns raw expression matrices into interpretable cell populations. Practitioners therefore face a recurring engineering decision: is an additional deep representation stage worth its compute and tuning cost, or do classical principal component analysis (PCA) pipelines already suffice? We address this question with a diagnostic benchmark of nine clustering pipelines on ten real datasets (90-5,685 cells, 19,046-41,480 genes, 4-11 cell types), augmented by a partial scVI V2 specialized comparison on seven datasets. The protocol integrates Optuna hyperparameter search, repeated-run robustness, Friedman/Wilcoxon-Holm/TOST testing, and Sobol total-order sensitivity analysis. The contrastive autoencoder achieved the highest mean Adjusted Rand Index (0.7872), but Holm-corrected tests did not establish dominance over the strongest baselines. Per-dataset analysis reveals three reproducible regimes: probabilistic variational autoencoder (VAE) variants help on the smallest datasets, deep autoencoders win on mid-scale data with multi-batch or many-type structure, and classical PCA pipelines remain competitive when linear projection already captures the dominant variation. Sobol indices identify learning rate ($S_T=0.70$) and latent dimensionality ($S_T=0.56$) as the dominant variance contributors, indicating where limited tuning budgets should be allocated. The contribution is therefore a dataset-aware and compute-conscious decision framework for biomedical AI pipelines supporting sustainable healthcare analytics, rather than a universal superiority claim.

Explore related subjects

Keep this discovery

BibTeXRIS

Nguyen Thanh Phong, Truong Viet Vu, Nguyen Ha Thu, Tran An Ky, Tran Hoang Thong, Le Pham Thuy Hien, Nguyen Thai Anh. 2026-07-28. When Does Deep Representation Learning Help Single-Cell Clustering? A Sensitivity-Aware Diagnostic Benchmark for Biomedical AI Pipelines. https://arxiv.org/abs/2607.25288

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG