arXiv · 2607.26741
Global 21cm Measurement Calibration Methodology
Abstract
21cm global signal observations present a unique set of calibration challenges owing to the absolute character of the required measurement. Since differential measurements on the sky cannot be used for observing the global signal, typically a number of calibration sources with differing noise temperatures and source impedances are used to determine the four noise parameters and the power gain of the amplification chain. Because of the broadband nature of the measurement, the antenna impedance varies with frequency in a manner different from the calibration sources, so that the simplest three-way Dicke switching strategy is not adequate. We present a self-contained and explicit derivation of the calibration equations and reconcile expressions from the early global 21cm observation literature with the results obtained following the amplifier noise representation formalism commonly used in the electrical engineering literature. We also present a condition in terms of M\"obius geometry on the complex $\Gamma $- (or $Z$-) plane defining the choice of calibration source impedances required.
Explore related subjects
Keep this discovery
Martin Bucher, Christian J. Kirkham, Eloy de Lera Acedo, Dirk I. L. de Villiers, Saurabh Pegwal. 2026-07-29. Global 21cm Measurement Calibration Methodology. https://arxiv.org/abs/2607.26741
Cite the original work for its findings. Save a collection to share your selection of sources.