SearcharxivSearch

arXiv · 2608.18969

Fuzzy Accuracy Compensates for Label Subjectivity in Classification of Skin Tone Using Wearable Photoplethysmography Signals

Abstract

We consider the problem of classification of skin tone using photoplethysmography (PPG) signals with labels of the ordinal six-class Fitzpatrick skin tones. A typical accuracy for this task is a poor 40-55 %. However, the labels are subjectively determined by comparing the skin with a colour chart, and hence contain widespread small-scale inaccuracies. By working with a "fuzzy accuracy", which deems a prediction of skin tone class to be correct if its difference from the labelled class is not greater than one, much higher accuracy is obtained which provides more convincing evidence that skin tone can be accurately predicted from PPG signals. Three machine learning approaches were used, namely deep learning or tree-based approaches on raw PPG signals, deep learning on image representations of the signals generated by the Symmetric Projection Attractor Reconstruction (SPAR) method, and machine learning on features extracted from the signals. The first method also employed a fuzzy version of the cross entropy loss function, which gave the best results. Tree-based models on raw signals give accuracies up to 55 % and higher fuzzy accuracies up to 96 %, while deep learning models on the SPAR images obtained lower results of 44 % accuracy and 85 % fuzzy accuracy. The machine learning on PPG features gave similar results to the SPAR method with accuracy of 42 % and fuzzy accuracy of 87 %. We have shown that classification of skin tone using PPG signals is possible with high fuzzy accuracy which implies that our modelling approach enables accurate prediction of skin tone class within at most one class of the observer's choice of class, from which we conclude that PPG signals are affected by skin tone in a discernible way.

Explore related subjects

Keep this discovery

BibTeXRIS

Padmini Krishnadas, Urs Hackstein, Alen Bosnjakovic, Philip J. Aston. 2026-08-19. Fuzzy Accuracy Compensates for Label Subjectivity in Classification of Skin Tone Using Wearable Photoplethysmography Signals. https://doi.org/10.1109/fuzz69877.2026.11626495

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

AUC Maximization from Biased Positive-unlabeled Data with Confidence

Maximizing the area under the receiver operating characteristic curve (AUC) is a standard approach to imbalanced binary classification. Although positive and negative data are required for maximizing the AUC, negative data are often difficult to collect in some real-world applications due to privacy concerns or the need for specialized expertise to annotate them. Thus, AUC maximization from positive and unlabeled (PU) data has been attracting attention. Existing methods assume that labeled positive data are unbiased samples from the true positive distribution. However, this ideal assumption is often violated in practice. In this paper, we propose a method to maximize the AUC from biased PU data. To address the bias, our key idea is to exploit {\it confidence}, i.e., the probability that an instance is positive, associated with the small number of labeled positive data. We derive an estimator of the AUC risk using biased PU data with confidence, enabling AUC maximization under such bias. We further show that the rewritten AUC risk induces a Bayes-optimal AUC ranking even when the available confidence is any strictly increasing transformation of the true posterior probability. We experimentally show the effectiveness of our method on eight real-world datasets.

cs.LG

Measuring the Value of World-Model Updates: A Counterfactual Utility Protocol for Continual Adaptation

Continual world models must decide whether new data justify changing the model. Fixed replay schedules and prediction-error triggers specify when to update, but neither reveals the value of an individual update: one deployment run cannot show how the same model would have performed at that moment had it held its parameters. We introduce the fork ledger, which branches a deployment stream at pre-registered decision points into matched update and hold continuations under common random numbers. It evaluates both continuations on the same episodes and records $\Delta R = R_{\mathrm{update}} - R_{\mathrm{hold}}$. Always applying one fixed update mechanism lowers return on all three simulated control tasks: CartPole ($-144.0$; checkpoint-bootstrap $95\%$ CI $[-185.4,-116.1]$, against a converged return near $650$), Walker ($-82.8$; $[-101.1,-61.7]$) and Cheetah ($-18.6$; $[-29.0,-6.6]$). Divergence is an outcome of applying the update, so the estimand counts every attempted fork; restricted to the $693$ of $720$ that did not collapse, CartPole and Walker are unchanged in sign ($-113.4$ and $-82.1$) and Cheetah becomes unresolved ($-3.9$; $[-17.5,+13.0]$). The task is the unit of inference: each contributes $240$ attempted forks over five pretrained checkpoints crossed with two drift directions. The ledger makes counterfactual utility observable for a fixed mechanism, allowing triggers to be judged by the updates they select rather than by surprise detection alone.

cs.LG

When More Is Not Better: Component Anti-Synergy in a P300 Speller

P300 brain-computer interface (BCI) spellers can provide hands-free communication for people with severe motor impairments. Modern pipelines combine multiple individually promising components, often assuming that 'more-is-better'. We tested this assumption using a four-component full-factorial experiment varying the inclusion of Euclidean Alignment (EA), xDAWN spatial filtering, subject calibration, and language model priors on a public P300 dataset. Performance was evaluated using accuracy, repetitions, and information transfer rate (ITR) with mixed-effects models. Results show that the value of components is conditional rather than additive. Calibration was the strongest singular contributor, while EA compensated for its absence in zero-calibration settings. Adding independently useful components could also reduce performance, revealing component anti-synergy. Contrary to conventional wisdom, LM support was not universally beneficial: its effect depends strongly on the strength of the underlying EEG pipeline, while results from a larger LM showed a similar pattern. Together, these findings challenge maximal 'all-on' pipeline design and highlight the value of selecting spatial and language-support components according to the quality of available EEG evidence.

cs.LG