arXiv · 2608.28781
Intracavity Dual-Resonance Stimulated Raman Spectroscopy with Cavity Ringdown Readout for Resolving Hydrogen Rotational Raman Transitions
Abstract
Gas-phase rotational Raman lineshape metrology of hydrogen (H2) is challenging due to its weak Raman scattering cross-sections and intrinsically narrow linewidths. We report the first measurement of the complete Dicke-narrowing evolution of the H2 rotational Raman transitions S0(1) and S0(0), enabled by intracavity dual-resonance stimulated Raman spectroscopy with cavity ringdown readout and kHz-level spectral resolution. Our results establish a benchmark for gas-phase Raman lineshape measurements and provide stringent constraints for regime-based pressure-dependent linewidth models.
Explore related subjects
Keep this discovery
Qinxue Nie, Guanda Lyu, Yue Yan, Wei Ren. 2026-08-28. Intracavity Dual-Resonance Stimulated Raman Spectroscopy with Cavity Ringdown Readout for Resolving Hydrogen Rotational Raman Transitions. https://arxiv.org/abs/2608.28781
Cite the original work for its findings. Save a collection to share your selection of sources.