Effects of Sequence Timing on the Spatio-Temporal Properties of 3D BOLD fMRI: A Formal Framework and Analysis

Abstract

3D sequences provide an alternative to 2D or multiband sequences for BOLD fMRI. The impact of acquisition time differences between slices is well understood for 2D or multiband sequences. For 3D sequences, k-space is partitioned into multiple segments and the final image depends on samples taken over an extended period of time. Any precise timing information is lost during reconstruction. A theoretical description of how sequence timing impacts 3D BOLD fMRI data properties is lacking in the literature. We present a formal framework that models sequence timing effects and draw connections to existing literature. The framework rests on the statistical description of a spin system that allows incorporation of BOLD signal changes and is completed by a general description of spatial encoding and image reconstruction. Using this formulation, we define three key images: the actual image reconstructed from a segmented 3D acquisition, an optimal reference image unaffected by sequence timing, and an error image representing their difference. Two sets of operators are defined that describe the generation of these images and allow us to analyse the effects of sequence timing independent of the object. All operators take the form of spatio-temporal filters. They mix signal content spatially and based on its temporal waveform. High-frequency BOLD signal content is affected more strongly compared to low-frequency content. Simulations demonstrate that while the total variance of 3D image time series can be reduced, spatio-temporal fidelity is increasingly lost. Furthermore, we hypothesize that the heightened sensitivity of 3D sequences to physiological noise (compared to 2D) is caused by sequence timing damping thermal noise more strongly than physiological fluctuations. The impact of motion and system instabilities on image time series needs to be studied further.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Samuel Bianchi, Klaas P. Pruessmann. 2026-09-17. Effects of Sequence Timing on the Spatio-Temporal Properties of 3D BOLD fMRI: A Formal Framework and Analysis. https://arxiv.org/abs/2609.20105

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Dipole-lets: a new multiscale decomposition for MR phase and quantitative susceptibility mapping

Nondipolar phase contributions can generate severe streaking artifacts during quantitative susceptibility mapping (QSM) inversion. We propose Dipole-lets, a dipole-adapted multiscale decomposition designed to identify phase components associated with streaking artifacts before and during susceptibility inversion. Dipole- lets combine an undecimated radial decomposition with an angular partition based on proximity to the magic cone. The resulting coefficients emphasize phase components near the magic cone, where nondipolar contributions may become relatively prominent. This information was incorporated into QSM reconstruction through a data- driven fidelity weight and a Dipole-let-based regularizer that models an additional nondipolar phase component. The methods were evaluated using modified simulated QSM data and an in vivo dataset. The data-driven weighting reduced streaking artifacts while preserving anatomical detail and improved quantitative reconstruction metrics compared with magnitude-weighted TV. The Dipole-let regularizer achieved streaking suppression comparable to L1-QSM and lower reconstruction error in the modified simulated dataset. In vivo experiments further demonstrated the applicability of the proposed approach to data with strong susceptibility-induced phase perturbations. Dipole-lets provide a multiscale representation for characterizing phase components associated with streaking artifacts and incorporating this information into QSM reconstruction, reducing streaking while preserving relevant susceptibility structures, and providing a flexible basis for future QSM reconstruction methods.

eess.IV

MTMed3D: A Multi-Task Transformer-Based Model for 3D Medical Imaging

In the field of medical imaging, AI-assisted techniques such as object detection, segmentation, and classification are widely employed to alleviate the workload of physicians and doctors. However, single-task models are predominantly used, overlooking the shared information across tasks. This oversight leads to inefficiencies in real-life applications. In this work, we propose MTMed3D, a novel end-to-end Multi-task Transformer-based model to address the limitations of single-task models by jointly performing 3D detection, segmentation, and classification in medical imaging. Our model uses a Transformer as the shared encoder to generate multi-scale features, followed by CNN-based task-specific decoders. The proposed framework was evaluated on the BraTS 2018 and 2019 datasets, achieving promising results across all three tasks, especially in detection, where our method achieves better results than prior works. Additionally, we compare our multi-task model with equivalent single-task variants trained separately. Our multi-task model significantly reduces computational costs and achieves faster inference speed while maintaining comparable performance to the single-task models, highlighting its efficiency advantage. To the best of our knowledge, this is the first work to leverage Transformers for multi-task learning that simultaneously covers detection, segmentation, and classification tasks in 3D medical imaging, presenting its potential to enhance diagnostic processes. The code is available at https://github.com/fanlimua/MTMed3D.git.

eess.IV

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.

eess.IV