SearcharxivSearch

arXiv · 2609.25437

Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development

Abstract

Data centers are being developed at an unprecedented pace, yet their energy and water impacts, and the spatial and temporal distribution of these impacts, remain poorly characterized. Data centers consume water for cooling (direct) and through electricity generation (indirect). Decisions on siting and cooling technology result in water-energy trade-offs that extend impacts beyond the facility's location. Existing assessment frameworks rely on facility efficiency metrics and average grid water intensity factors, suppressing the temporal impacts of data center load and generation availability. They also attribute indirect consumption to the facility's location rather than to the generators (and corresponding hydrologic regions) that respond to the added load, misattributing spatial impacts. To close this gap, we develop a computational model of the data center-energy-water nexus that links facility cooling and electricity demand with hourly economic dispatch, generator-level water consumption, and monthly subbasin depletion. Built on open-source data, the model resolves where and when water is consumed, and where this consumption compounds existing water risk or creates new risk. Using the model, we study different cooling configurations and proposed developments in the state of Michigan. Air-cooled data centers halve total water consumption relative to evaporative cooling, but increase electricity demand and raise indirect water consumption by one-third, shifting the water footprint from the facility to generators. Mapping these changes to subbasins reveals depletion increases beyond the data center sites, in regions that facility-level reporting may overlook. These results show that data center water and energy impacts cannot be assessed in isolation, motivating the need for integrated modeling to inform siting, design, and reporting practices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Garrett Alston, Nancy Love, Rabab Haider. 2026-09-21. Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development. https://arxiv.org/abs/2609.25437

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Observability and parameter estimation of a generic model for aggregated distributed energy resources

We propose a novel framework for estimating the parameters of an aggregated distributed energy resources (DER A) model. First, we introduce a rigorous method to determine whether all model parameters are estimable. When they are not, our approach identifies the subset of parameters that can be estimated. The proposed framework offers new insights into the number and specific parameters that can be reliably estimated based on commonly available measurements. It also highlights the limitations of calibrating such models. Second, we introduce a Kalman filtering method to calibrate the DER A model. Since we account for nonlinear effects such as saturation and deadbands, we develop a specific mechanism to handle smoothing functions within the Kalman filter. Specifically, we consider the extended and the unscented Kalman filter. We demonstrate the effectiveness of the proposed framework on a modified IEEE 34-node distribution feeder with inverter- based resources. Our findings align with the North American Electric Reliability Corporation's parameterization guideline and underscore the importance of model calibration in accurately capturing the collective dynamics of distributed energy resources installed on distribution systems.

eess.SY

Salted Fisher Information for Hybrid Systems

Discrete events change how parameter-influence propagates in hybrid systems. Prevailing Fisher information for- mulations assume that sensitivities evolve smoothly according to continuous-time variational equations and therefore neglect the sensitivity updates induced by discrete events. This paper derives a Fisher information matrix formulation compatible with hybrid systems. To do so, we use the saltation matrix, which encodes the first-order transformation of sensitivities induced by discrete events. We call the resulting formulation the salted Fisher information matrix (SFIM). The proposed framework unifies continuous information accumulation during flows with discrete updates at event times. We also show that hybrid persistence of excitation is sufficient for the SFIM to be positive definite

eess.SY

Min-Max Grassmannian Optimization for Online Subspace Tracking

We propose GeRoST (Geometrically Robust Subspace Tracking), an online subspace tracking algorithm that models uncertainty in a subspace using a Grassmannian ball. We derive an exact scalar dual for the worst-case subspace problem, establish conditions for a unique worst-case subspace and a Riemannian gradient, and characterize the minimum radius needed to cover a dimensional extension of the target subspace. Each update uses either a spectral direction computed in a reduced subspace or the gradient of the window reconstruction loss. Our numerical experiments show that GeRoST achieves lower mean post-fault prediction error than GREAT in system identification. In video separation, it achieves higher precision and a better precision--recall balance, as measured by the F$_1$ score, than both GREAT and GRASTA at the reported thresholds, with lower recall and longer runtime.

eess.SY