Searcharxiv⌕ Search

arXiv · 2610.02112

Binary Phase Retrieval of Cosine Transforms via Local Curvature Minimization

Abstract

Cosine transforms see frequent use in image and video compression due to their ease of computation and high energy compaction. This has sparked interest within the optics community in computing cosine transforms optically for compression. When imaging in the Fourier plane to capture a cosine transform, one encounters a phase retrieval problem: optical fields have both magnitude and phase, but cameras only capture the magnitude of the field. Cosine transforms restrict the phase retrieval problem to a binary domain as opposed to the unit circle, but general phase retrieval solutions do not leverage this. In this work, we demonstrate that sign errors in phase retrieval for cosine transforms result in a significant increase in the magnitude of the Hessian of the transform at the error. Motivated by this, we develop an algorithm to solve this binary phase retrieval problem by minimizing the curvature of the reconstructed cosine transform. We demonstrate via computational experiments that given the magnitude of the cosine transform of an image, we can consistently reconstruct the original image within a multiscale structural similarity index of 0.95. We show that the solve time grows approximately linearly with the number of pixels solved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ronald Ogden, Shwetadwip Chowdhury, Takashi Tanaka, David Fridovich-Keil. 2026-10-01. Binary Phase Retrieval of Cosine Transforms via Local Curvature Minimization. https://arxiv.org/abs/2610.02112

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Trajectory Stitching for Solving Inverse Problems with Flow-Based Models

Flow-based generative models have emerged as powerful priors for solving inverse problems. One option is to directly optimize the initial latent code (noise), such that the flow output solves the inverse problem. However, this requires backpropagating through the entire generative trajectory, incurring high memory costs and numerical instability. We propose MS-Flow, which represents the trajectory as a sequence of intermediate latent states rather than a single initial code. By enforcing the flow dynamics locally and coupling segments through trajectory-matching penalties, MS-Flow alternates between updating intermediate latent states and enforcing consistency with observed data. This reduces memory consumption while improving reconstruction quality. We demonstrate the effectiveness of MS-Flow over existing methods on image recovery and inverse problems, including inpainting, super-resolution, and computed tomography.

eess.IV↗

Rapid quantitative chemical composition mapping using model-based MRI reconstruction with field inhomogeneity correction

Magnetic resonance spectroscopic imaging methods are particularly attractive for chemical engineering applications, including the monitoring of chemical reactions, where a rapid assessment of spatial variations in chemical composition is required. Conventional approaches, such as chemical shift imaging, introduce an additional spectral-encoding dimension, which substantially increases acquisition time. Consequently, fast spatially resolved spectroscopy remains an active research topic. This work uses a model-based reconstruction framework that embeds a priori spectral knowledge of the involved chemical components into the forward model to accelerate composition mapping. It allows for the reconstruction of molar ratio maps for individual chemical components without acquiring high-resolution spectra. Extending from previous studies, the proposed model accounts for inhomogeneities of the main field, which become more pronounced in systems with larger bores relevant for process engineering. Phantom experiments employing a 2D multi-gradient echo sequence demonstrate the ability to determine molar ratios for chemical components with single peaks as well as multiple peaks in their spectra. The bias and precision of the method remain around 0.01 mol/mol and 0.09 mol/mol, respectively, for a 20 s scan, indicating suitability for dynamic processes. Finally, acquisition time can be reduced further by applying sparse k-space sampling, potentially shortening the scan to 5 s with only minor degradation in quantitative performance.

eess.IV↗

MorphoBranch: A Fine-Structure-Preserving Workbench for Morphometric Analysis of Branched Cellular Structures

Background and Objectives: Fluorescence-labeled cellular arbors provide readouts of neuronal and microglial morphology, but fine and weakly labeled processes are prone to fragmentation and false connections that bias skeleton-based measurements. We present MorphoBranch, a fine-structure-preserving, human-reviewable workbench for morphometry of branched cellular structures. Methods: MorphoBranch combines a deterministic Morphometry Engine with an LLM-assisted Refinement Engine. The Mor- phometry Engine implements an image-to-graph workflow integrating multiscale structural evidence extraction, hysteresis segmen- tation, evidence-constrained skeleton refinement, and graph-based morphometry. The Refinement Engine maps natural-language requests to registered actions for parameter adjustment, preview execution, metric reporting, and unsupported-request handling, while image processing and quantitative computation remain deterministic and reviewable. Results: MorphoBranch was evaluated on two public neuronal axon datasets, AxonMIP and AxonStack, and the in-house Cell- Morph dataset of microglial fluorescence images. It achieved the highest Skeleton F1 and clDice and the lowest length-estimation error among the evaluated methods on all three datasets, while also achieving the highest Dice and IoU on AxonMIP and Axon- Stack. Across 150 natural-language tasks, the Refinement Engine achieved a 94.0% end-to-end success rate. Conclusions: These results demonstrate that MorphoBranch provides a reproducible, human-reviewable workflow for mor- phometric analysis of branched cellular structures. It supports fine-structure-preserving quantification across neuronal axon and microglial fluorescence images while maintaining inspectable and reproducible analysis workflows.

eess.IV↗