Searcharxiv⌕ Search

arXiv · 2610.18728

Direct correlation of intravoxel incoherent motion imaging based on implicit neural representations and histopathology in pediatric Wilms tumors: can it differentiate between subtypes?

Abstract

Wilms tumor (WT) is a heterogeneous pediatric renal malignancy. Invasive procedures to establish histology prior to pre operative treatment are not recommended by the International Society of Pediatric (SIOP) Oncology Renal Tumor Study Group, yet different tissue components are associated with different responses to therapy (SIOP Umbrella protocol). Intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) may improve subtype differentiation before surgery as a noninvasive radiographic biomarker by capturing both diffusion and perfusion characteristics, as opposed to the conventionally used apparent diffusion coefficient (ADC). The objective of this study is to evaluate the discriminative performance of IVIM MRI in differentiating WT subtypes. IVIM provides quantitative parameters that disentangle the diffusion coefficient (D), incoherent blood flow (pseudodiffusion Dstar) and perfusion fraction (f). This retrospective study included thirthy children with WT. Standardized 1.5T MRI with 10 b value diffusion weighted imaging (DWI) was performed. IVIM parameters were estimated using a selfsupervised implicit neural representations network and were correlated with histopathology via a patient specific 3D printed cutting guide. Statistical analyses included mixed models, receiver operating curve analysis, and logistic regression. Thirty lesions were MRI histopathology correlated on slice level. Significant subtype differences were observed for Dstar stromal versus epithelial (p = 0.024), regressive tumors (p = 0.031) and mixed WT tumors (p = 0.043). ADC showed no significant subtype differences. Direct MRI histopathology correlation enabled differentiation between stromal subtype and epithelial, mixed and regressive subtype on macroscopic slice level using Dstar.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G. C. Arends, M. Fitski, J. Harbers, J. N. van der Beek, R. R. de Krijger, M. M. van den Heuvel-Eibrink, A. F. W. van der Steeg, F. F. J. Simonis, E. Versteeg, A. S. Littooij, C. M. W. Tax. 2026-10-13. Direct correlation of intravoxel incoherent motion imaging based on implicit neural representations and histopathology in pediatric Wilms tumors: can it differentiate between subtypes?. https://arxiv.org/abs/2610.18728

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Photoacoustic imaging of human brain function through intact adult skulls

Blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) has revolutionized noninvasive imaging of human brain function, but it indirectly senses deoxyhemoglobin through water-proton relaxation and relies on bulky, costly, noisy, enclosed, superconducting-magnet scanners. In contrast, photoacoustic computed tomography (PACT) directly probes hemoglobin absorption using a more compact, lower-cost, quieter, open, magnet-free system. However, functional PACT of the adult human brain has so far been demonstrated only after surgical skull removal, because the skull strongly attenuates optical and acoustic signals. Here, we demonstrate non-invasive transcranial functional PACT (T-fPACT) through the intact adult skull. A densely packed, high-channel-count (3,072-element) hemispherical ultrasonic array provides near-$2π$-steradian simultaneous acquisition, enabling high sensitivity and single-shot three-dimensional imaging at 20 Hz that eliminates motion blurring. Participant-specific stabilization further enables measurement of small task-evoked hemodynamic responses over the entire task duration. In healthy adults, T-fPACT localized responses to expected sensorimotor regions, distinguished task-specific motor representations, and yielded consistent localizations across repeated task runs and visits. Comparison with high-field (7 T) fMRI showed spatially corresponding functional regions, while dual-wavelength imaging revealed distinct hemoglobin-weighted responses. These findings overcome the long-standing skull barrier in human brain PACT and establish non-invasive, rapid volumetric photoacoustic imaging of brain function.

physics.med-ph↗

Continuous 3-D Latent Diffusion for Medical Image Generation and Reconstruction

High-resolution three-dimensional (3-D) medical latent diffusion remains limited by the cost of decoding full volumes, which existing latent autoencoders (AEs) handle through overlapping sub-volume decoding. We propose a continuous 3-D latent diffusion model framework for computed tomography (CT) and magnetic resonance imaging (MRI) generation and measurement-guided reconstruction, built on a coordinate-rendering autoencoder (CoRe-AE). Its decoder applies its convolutional stage once on the compact latent grid and renders voxel intensities from spatial coordinates through a lightweight implicit head, evaluated in memory-bounded chunks. This design avoids overlapping sub-volumes and remains differentiable with respect to the latent, so that the decoder can be used inside measurement-guided reconstruction. The framework was evaluated on CT volumes of 512\textsuperscript{3} voxels and MRI volumes of 256\textsuperscript{3} voxels. At 512\textsuperscript{3}, the decoder was 4--18 times faster than the MAISI and 3D MedDiffusion AEs and required the lowest peak graphics processing unit (GPU) memory, including when its gradient was computed. CoRe-AE also achieved the highest peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) among the evaluated AEs on both modalities. The resulting frozen 3-D latent prior generated full volumes without patch seams and, without retraining, reconstructed sparse-view CT and accelerated MRI through hard data consistency, within 2.4--4.9 dB PSNR of the pixel-domain decomposed diffusion sampler (DDS). A single volumetric latent prior thus supports both generation and reconstruction of high-resolution medical volumes on one GPU. Our code will be made available at https://github.com/Mellak/continuous-3d-latent-diffusion/.

physics.med-ph↗

Automated carotid artery atherosclerotic inflammation segmentation in PET using MSR-Net

Objective. To develop an automated method for segmentation and uptake quantification of carotid atherosclerotic inflammation on 64Cu-CANF-comb PET while accounting for partial-volume and tissue-fraction effects. Approach. Synthetic carotid PET images with known fractional-volume ground truth were generated by combining MR-derived high-resolution activity maps with GATE Monte Carlo simulation incorporating major PET physical processes and matched to the Biograph mMR acquisition and reconstruction. A two-stage network first localized the carotid vessel wall from T1-weighted MR and then estimated voxel-wise inflammation fraction from masked PET. Both stages used a multiscale residual (MSR) convolutional backbone. Performance was compared with U-Net, Transformer U-Net, DUCK-Net, and iterative Yang partial-volume correction. Main results. In a two-alternative forced-choice study, five nuclear-medicine physicians identified real images with 54% accuracy (54/100; Wilson 95% CI 0.44-0.63; exact binomial p = 0.48). On 184 simulated test slices from five held-out patients, the proposed method achieved a weighted DSC of 0.79, compared with 0.73 for U-Net, 0.69 for Transformer U-Net, and 0.75 for DUCK-Net, with corresponding HD values of 1.85, 2.29, 2.32, and 2.23 voxels. Patient-cluster bootstrap comparisons favored the proposed method for DSC and HD against all three baselines (Holm-corrected p <= 0.031). Overall ENRMSE was 0.24 versus 0.59, 0.68, and 0.59 for the three DL baselines and 0.57 for iterative Yang. In seven patients, corrected SUV showed a positive association with MR-derived lipid-rich/necrotic core with hemorrhage. Significance. The proposed framework improved carotid PET segmentation and uptake quantification under simulated conditions. The patient analysis is preliminary and requires external validation with biological reference standards before clinical deployment.

physics.med-ph↗