Searcharxiv⌕ Search

arXiv · 2610.32076

Stability Enhancement of Cascaded DC Systems via Source Output-Impedance Reshaping Using Model-Free Control

Abstract

Cascaded DC systems may become unstable through source-load impedance interactions even when their constituent converters are locally stable. This paper proposes a source-side model-free control (MFC) method that reuses bus-voltage feedback to reshape the source output impedance while preserving nominal reference-to-output dynamics. The controller uses only nominal source-loop information and requires neither a load-converter model nor load-side measurements. A current-controlled buck source supplying a regulated buck-resistor load that exhibits constant-power load (CPL) behaviour at low frequencies is used as the case study. Impedance analysis predicts that the proposed MFC increases the maximum stable load power by approximately 50%, thereby improving the stability margin of the cascaded system. Switched-model simulations confirm preservation of the nominal reference-to-output response and show that the MFC-controlled system remains stable at load levels for which the baseline system becomes unstable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wanrong Li, Shuhan Hu, Hengping Xiong, Runnan Wang, Huawei Yuan, Jianguo Zhu, Sinan Li. 2026-10-23. Stability Enhancement of Cascaded DC Systems via Source Output-Impedance Reshaping Using Model-Free Control. https://arxiv.org/abs/2610.32076

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Controller-Agnostic Runtime Safety Certificates for Tool-Using AI Agents via Data-Driven Robust Reachability

Software agents built on large language models act by issuing tool calls, some of which cannot be undone. To control theory the model is an opaque feedback controller, replaced every few months, whose closed loop cannot be analyzed directly. We propose a runtime filter, or shield, between any such controller and its environment that certifies a bound on the probability of reaching an unsafe condition during a bounded task. Given a predicate abstraction and candidate successor sets, everything else comes from logs: the loop becomes a finite controlled Markov chain, the estimated kernel is surrounded by a distribution-free confidence region, and robust reach-avoid value iteration runs over it. The certificate is probably approximately correct and uniform over controllers respecting the filter, so one model may replace another without recomputation. In all tested datasets the true risk stayed within certificate and budget; in a file-system sandbox the filter stays sound against a hazard the logs barely covered, where a plug-in baseline certifies safety and fails; and it holds seven controllers, three of them open-weights models, to zero unsafe outcomes in 1050 episodes.

eess.SY↗

Scalable Reservoir Computing for Disturbance Localization and Identification in Power Grids

In this paper, we present a novel method for the localization and temporal waveform reconstruction of disturbances in complex power grids using observations of system state variables. Although various methods exist for detecting these events, accurately identifying and responding to them remains a significant challenge due to the grid's size, speed, complexity, and inherently dynamic behavior. We formulate a method for disturbance localization and reconstruction based on reservoir computing, a recurrent neural network architecture. We show that our method is able to recover the time dependence of previously unobserved disturbances, is robust to missing information, and can operate online. The approach requires only observed system data and knowledge of the network topology, without requiring a physical model of the system dynamics, and can recover simultaneous disturbances occurring at multiple locations. We implement a scalable parallelized reservoir architecture and demonstrate our algorithm on test IEEE cases and a reduced WECC system.

eess.SY↗

Model-Free Output-Admittance Reshaping for Stability Enhancement of Grid-Connected Inverters

Grid-connected inverters can be unstable when their current-control loops interact with an uncertain external network. Returning the existing controller to improve damping also alters current tracking because tracking dynamics and output admittance are coupled. This paper adds a local model-free control (MFC) loop around the existing current controller to reduce output admittance while closely preserving nominal current-tracking dynamics. The added loop uses local inverter parameters without an external grid or neighbouring converter model. A Norton formulation separates reference tracking from the current response to terminal-voltage disturbances and establishes a tracking-preservation condition for admittance reshaping. Reducing the disturbance response makes the inverter behave more like an ideal controlled current source. Averaged-model simulations show reductions exceeding 65% in the magnitudes of all four dq output-admittance elements over 10-200 Hz, with closely preserved current-tracking dynamics. Generalised Nyquist analysis predicts small-signal stability for all sampled grid-impedance cases with MFC, compared with 90.0% without MFC.

eess.SY↗