Searcharxiv⌕ Search

arXiv · 2610.36357

Multi-time-scale Control of Power Systems

Abstract

The power grid has been dominated by large synchronous generators and clearly separated control layers. Today, power-electronics energy conversion interfaces are rapidly being deployed calling for another look at system-level control hierarchies. This article examines how multi-time-scale modeling, feedback control, and feedback optimization can help reinterpret the traditional organically grown hierarchy of primary control, automatic generation control, and economic dispatch, and enable new approaches for control of contemporary power systems. Beginning with an overview of power system models and conventional operational practices, the article develops connections to modern control architectures that can coordinate heterogeneous resources, account for operational constraints, and exploit faster actuation without overlooking first-principles physics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Emiliano Dall'Anese, John W. Simpson-Porco, Florian Dorfler, Saverio Bolognani, Sairaj Dhople. 2026-10-26. Multi-time-scale Control of Power Systems. https://arxiv.org/abs/2610.36357

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Electric Vehicle Scheduling and Carbon-Aware Energy Dispatch for Charging Stations

Electric vehicle (EV) charging stations integrating photovoltaic (PV) generation, battery storage, and bidirectional grid exchange must coordinate access to limited chargers with energy supply while considering both energy cost and carbon emissions. This paper proposes a solver-free greedy heuristic (SFGH) for dynamic vehicle scheduling (VS) and a twin delayed deep deterministic policy gradient (TD3) controller for carbon-aware energy dispatch (ED). SFGH assigns EVs according to reductions in service delays, and TD3 controls battery operation to balance energy costs and carbon emissions while meeting the resulting charging demand. The model allows both PV and battery exports, accounting for export revenue and carbon credits. Simulations on year-long case studies show that SFGH--TD3 achieves the lowest accumulated service delay, energy cost, and carbon emissions among the evaluated heuristic and multi-agent deep reinforcement learning (DRL) configurations.

eess.SY↗

Phase-Coordinated Model Predictive Control for AI Training Power Smoothing

Periodic power fluctuations from artificial intelligence (AI) training workloads can excite oscillations in power systems. This paper proposes a model predictive control (MPC) framework that exploits short start-time delays to mitigate power fluctuations at the computing source. By coordinating the relative phases of independent training jobs, the proposed method reduces the superposition of oscillatory power components without interrupting running jobs or requiring additional power-smoothing hardware. To obtain a tractable optimization formulation, cosine and sine projections are employed to quantify the dominant oscillatory power components, and their magnitudes are used to construct a convex quadratic power-smoothing objective. The receding-horizon framework updates launch decisions as new workload information becomes available while maintaining scheduling feasibility under limited computation time. Numerical results demonstrate reductions of 74.39\% in mean-square power fluctuations within the 0.2--2-Hz band and 46.6\% in power standard deviation, with an average launch delay of 2.188~s. All launch deadlines are satisfied, and the maximum end-to-end computation time is 0.390~s, below the 0.50-s MPC update period.

eess.SY↗

A Topology-Aware Neural Network for Fault Location With Missing Measurements

This paper proposes a topology-aware neural network-based fault locator (TANFL) for radial distribution feeders, which uses voltage and current phasors obtained after the decay of fault induced transients, as well as feeder connection relationships and line parameters, as inputs. The shared bus encoder, bus readout module, and gated line readout module work together to identify the faulty bus or line and estimate the continuous fault location on the selected line. During training, explicit missing data indicators and random bus data block masking are introduced, enabling a single trained model to handle both complete measurement sets and scenarios where any permitted bus measurement device fails. On the IEEE 15 bus feeder, this paper compares TANFL with a conventional multilayer perceptron (MLP) and the formula-based localization method under identical data, measurement availability scenarios, and evaluation metrics. On the test partition, TANFL outperforms the conventional MLP; with complete measurements, its line fault location performance is slightly lower than that of the formula-based method, but in the average results for scenarios with one missing bus measurement block, its accuracy is the highest among the three methods at a 5% tolerance.

eess.SY↗