Searcharxiv⌕ Search

arXiv · 2610.38953

Guidance-Coupled Nullspace Drifting for One-Step Medical Image Reconstruction

Abstract

Generative reconstruction can recover high-quality images from undersampled acquisitions, but state-of-the-art generative priors commonly rely on iterative sampling. Reducing the number of iterations lowers inference cost but also removes opportunities for progressive distributional refinement, making it difficult to retain image realism without sacrificing reconstruction fidelity. Drift modeling offers an alternative by shifting progressive refinement to training, thereby enabling one-step sampling without an iterative inference trajectory. Existing drifting methods, however, do not account for the imaging operator when modeling distributional drift. We propose DriftRecon, a generative method for one-step medical image reconstruction that performs drifting directly in the nullspace of the imaging operator. DriftRecon uses nullspace-restricted noise to construct training samples and a multiscale generator that incorporates measurement conditioning across resolution levels, with its generated component projected onto the operator nullspace. To control the fidelity--realism trade-off at inference, a conditional guidance parameter continuously steers the same generator between measurement-conditioned and unconditional generation. We derive a guidance-dependent similarity-kernel temperature schedule that preserves the guidance-weighted mass receiving strengthened supervision, thereby progressively localizing drift interactions as guidance increases to limit the associated loss of reconstruction fidelity. Experiments in sparse-view CT and accelerated MRI reconstruction show that DriftRecon outperforms established generative reconstruction methods and recent drifting models while producing reconstructions in a single forward pass.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Tuna Alatan, Agah Server Tapan, Şaban Öztürk, Muhammad Usama Mirza, Bilal Kabas, Ge Wang, Tolga Çukur. 2026-10-28. Guidance-Coupled Nullspace Drifting for One-Step Medical Image Reconstruction. https://arxiv.org/abs/2610.38953

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Discovering shared interpretable operations in image compression autoencoders

With the increasing adoption of deep learning for applications such as image compression, improvements in the rate-distortion trade-off have been achieved at the cost of increasingly larger and more opaque ''black-box'' models. Autoencoders are among the most widely used architectures for this task; however, without a clear understanding of their internal behavior, these models tend to grow in complexity to achieve more performance gains. In this paper, we investigate whether universal behaviors can be detected from the internal operations of bias-free autoencoders through Jacobian analysis. If such behaviors exist, they may be extracted to design low-complexity image compression models inspired by high-complexity deep learning architectures.

eess.IV↗

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression that lacks explicit correspondence constraints. We introduce SCoPE-Reg, combining dual-input state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $μ$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the best-performing baseline, reduces peak error on CAMUS by 56% ($12.5\to5.5$ mm), and registers $100%$ and $80%$ of frames within $3$mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. By coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, SCoPE-Reg becomes viable at native acquisition resolution during intervention, whereas previous methods had to compromise on accuracy, reliability or frame rate. Supplementary code: https://github.com/TIO-IKIM/SCoPE-Reg.

eess.IV↗

Blind Video Denoising for Vocal Tract rtMRI using a Self-Supervised Ensemble

Real-time magnetic resonance imaging of the vocal tract makes speech articulation directly observable, but the trade-off between temporal resolution and signal quality introduces substantial noise and obscures fine articulatory detail. Since clean references cannot be acquired for a moving vocal tract, supervised denoising approaches are not applicable in this setting. We propose a self-supervised denoising framework that combines spatiotemporal super-resolution learning with pseudo-supervision derived from a variance-stabilized non-local means filter. A dual-model fusion strategy balances noise suppression and preservation of high-frequency articulatory structure. Experiments on the USC-75 multi-speaker dataset under natural noise conditions show that the ensemble raises the signal-to-noise ratio by 11.9 dB on unseen subjects while attaining more high-frequency articulatory content in the frames. Among tuned implementations of anisotropic diffusion, block-matching filtering, non-local means and pre-smoothed non-local means, every configuration that achieves comparable noise suppression does so at the cost of high-frequency content or of structural fidelity. Under severe added Gaussian, Rayleigh and Rician noise, peak signal-to-noise ratio improves by 7.6 to 11.8 dB and structural similarity roughly triples. An ablation shows that the variance-stabilized pseudo-supervision is an essential element for denoising, and that the effect is attributable to the hard thresholding contained in the stabilization transform.

eess.IV↗