Searcharxiv⌕ Search

arXiv · 2610.40699

CalibCause: A Quality-Gated, Interpretable and Calibrated Deep Learning Framework for Diabetic Retinopathy Grading

Abstract

Most deep learning systems for diabetic retinopathy (DR) grading are evaluated on a single data source, with limited evidence of cross-site generalisation, uncertainty calibration, and interpretability. We propose CalibCause, a quality-gated mixture-of-experts framework that combines per-expert visual explanations, label-free image-quality conditioning, knowledge distillation, and calibrated confidence with deferral. We evaluated the framework using 51,310 fundus images from EyePACS, DDR, and APTOS 2019, with IDRiD and DeepDRiD for external testing. Evaluation included pooled testing, leave-one-environment-out experiments, paired bootstrap confidence intervals, and local grade-threshold adaptation. On the pooled test split, the label-free distilled student achieved quadratic weighted kappa (QWK) of 0.863 and accuracy of 0.865 with 27.8 million parameters, 52% fewer than its teacher. Across held-out environments, the label-free model achieved mean QWK of 0.741 compared with 0.743 for a plain ConvNeXt-Tiny baseline, while adversarial invariance did not improve cross-site grading accuracy. Refitting grade thresholds using 200 labelled images increased held-out EyePACS QWK from 0.533 to 0.621 for the label-free model. After vector scaling, expected calibration error ranged from 0.025 to 0.036 across CalibCause variants, and deferring the least confident 20% of images increased student accuracy from 0.865 to 0.923 on the remaining images. These findings demonstrate that quality-aware grading, interpretable expert routing, model compression, and calibrated deferral can be integrated without sacrificing cross-site performance relative to a plain baseline, although reliable deployment still requires local validation and adaptation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sohaib Sulman, Muhammad Atif Saeed, Akhtar Jamil, Alaa Ali Hameed, Roland Aydin. 2026-10-28. CalibCause: A Quality-Gated, Interpretable and Calibrated Deep Learning Framework for Diabetic Retinopathy Grading. https://arxiv.org/abs/2610.40699

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Cyst-X: A Multicenter MRI Benchmark for Pancreatic Cyst Risk Stratification and Cross-Institutional AI

Intraductal papillary mucinous neoplasms (IPMNs) are pancreatic cancer precursors, and guideline-based risk stratification both over-treats indolent lesions and misses progression. We present Cyst-X, a public benchmark of 1,461 T1-weighted (T1W) and T2-weighted (T2W) MRI volumes from 764 patients at seven centers, with expert pancreas masks, risk labels, splits and reference AI risk-prediction models. PanSegNet segmented the pancreas with Dice of 86.34% (T1W) and 89.26% (T2W) on held-out centers. For the primary task, high-risk versus low-risk IPMN, a 3D DenseNet-121 achieved cross-validated AUCs of 74.59% and 73.45%; complementary broad binary and three-class tasks reached 78.67--81.28% and 73.47--75.76%. Because patient images often cannot be pooled across institutions, we also simulated federated learning across the seven centers. On T2W MRI, FedProx was similar to centralized training in center-averaged external AUC (71.00% versus 71.18%) but not in pooled AUC (62.35% versus 77.49%). Radiologist comparisons showed cohort-dependent sensitivity--specificity tradeoffs. Cyst-X supports reproducible method development and identifies within-IPMN risk discrimination and cross-center score comparability as open challenges.

eess.IV↗

Beyond Visibility: Real-Time Surface Accessibility Fields from Sparse LiDAR

Understanding which surfaces a given tool can physically access is fundamental to robotic interaction, yet 3D perception typically stops at geometric reconstruction or visibility estimation. Visibility does not imply accessibility: a visible point may still be blocked by tool geometry or approach-corridor clearance. We propose the Accessibility Field: a per-point surface accessibility labelling, computed from streaming sparse LiDAR and updated at sensor rate as the platform moves. Our GPU-based method evaluates surface points against precomputed tool-geometry kernels across rotated approach orientations, underpinned by a scan-centric TSDF integration scheme suited to non-repetitive sensors such as the Livox Mid-360. The system is tool-agnostic, requires no prior scene model, and runs in real time on both workstation and Jetson Orin edge hardware. On synthetic primitives, our method achieves F1=90.8%, against 69.8% for a Hidden Point Removal baseline; ablations within our own pipeline give 81.5% replacing the TSDF query with a point-cloud collision check, and 33.9% replacing scan-centric integration with projective, nvblox-style integration. On a mature synthetic Pinus radiata model, the method labels 56.8% of visible pine branch surfaces as physically inaccessible.

eess.IV↗

Forecasting Brain Tracer Distribution from Pre-Contrast MRI: A Comparison of Direct Regression and Flow Matching

The brain fluid clearance system can be studied with intrathecal contrast-enhanced magnetic resonance imaging (MRI). By injecting a tracer into the spinal canal and performing MRI over 24--48\,h, one can measure how a tracer injected into the cerebrospinal fluid spreads through the brain. As this is an invasive procedure requiring several MRI scans, we ask how much of the later tracer distribution can be predicted from the pre-contrast scan and elapsed time alone. Using 104 training patients (878 MRI volumes), we compared a direct image-to-image regression model with a more complex generative model based on conditional flow matching, and tested both on 23 held-out patients and on 51 patients from a separate cohort with idiopathic normal pressure hydrocephalus (iNPH). Relative to simply copying the pre-contrast scan, the direct model reduced the mean absolute error (intensities normalized to $[0,1]$) from 0.089 to 0.036, about 60\%, in held-out patients and from 0.075 to 0.056, about 25\%, in the iNPH cohort. The reduction held in every sampled elapsed-time interval and brain compartment, and errors remained largest at 20--30\,h and in the ventricles, where enhancement is strongest. Its predicted change maps agreed with the observed tracer enhancement rather than only reproducing anatomy. The generative model was less accurate in both cohorts. A substantial part of the later tracer distribution is therefore predictable from the patient's brain anatomy as seen on pre-contrast MRI, and the added model complexity gave no benefit at this data scale. Whether this accuracy suffices for a given clinical use remains to be established; with prospective validation, such forecasts could help simplify the MRI protocol used to assess brain clearance.

eess.IV↗